Yes it’s the manager responsible for comms, you need 1.19 or above for the latest integration - if you get that updated you’ll have access to the new features such as force charge / discharge work modes.
Plus there are many fixes in the inverter, and maxsoc now works correctly.
Search found 844 matches
- Tue May 14, 2024 7:57 pm
- Forum: Firmware
- Topic: KH10.5 Latest firmware version
- Replies: 10
- Views: 246
- Tue May 14, 2024 6:34 pm
- Forum: Firmware
- Topic: KH10.5 Latest firmware version
- Replies: 10
- Views: 246
Re: KH10.5 Latest firmware version
The very latest versions are :-
Master 1.30
Slave 1.01
Manager (ARM) 1.22
Master 1.30
Slave 1.01
Manager (ARM) 1.22
- Tue May 14, 2024 10:30 am
- Forum: Customer/End User Help
- Topic: G8 inverter problems
- Replies: 21
- Views: 348
Re: G8 inverter problems
The installer attended today. Winced at the voltage level. Spent no more than five minutes configuring the inverter such that it is happy at higher voltages. Now all I need is some sun! Time to chase my complaint with the DNO, who have known about this for eight months and done nothing. Hopefully t...
- Mon May 13, 2024 10:01 pm
- Forum: Mobile App Help
- Topic: help understanding app overview page
- Replies: 4
- Views: 98
Re: help understanding app overview page
Ok, if it’s the V2 app from the ‘plant’ page (the picture of the house), swipe left and you will see this screen -
You can see the export total for the Day, Month or Year by changing the selection.
You can see the export total for the Day, Month or Year by changing the selection.
- Mon May 13, 2024 9:17 pm
- Forum: Mobile App Help
- Topic: help understanding app overview page
- Replies: 4
- Views: 98
Re: help understanding app overview page
Hi, which app are you using, is it the V1 app (blue background) or the V2 app (black background) ? The data screen is a snapshot taken every 5 minutes so not a real time view, and when larger appliances turn on and off you sometimes see strange numbers (sampling errors) which will correct after the ...
- Mon May 13, 2024 9:03 am
- Forum: Customer/End User Help
- Topic: Force charge option missing
- Replies: 4
- Views: 121
Re: Force charge option missing
No problem, For what you are doing I would stick with the old charge periods, but if you want to find the schedules, on the foxesscloud web go to this screen and click the icon circled red. 111.jpg If it comes up with this page you are fully up to date and can set schedules 112.jpg If it doesn't it ...
- Sun May 12, 2024 5:14 pm
- Forum: Customer/End User Help
- Topic: G8 inverter problems
- Replies: 21
- Views: 348
Re: G8 inverter problems
Ahhh ok sorry my bad, I was thinking it was a hybrid inverter, but it’s a PV inverter (G series). 254V is high, the maximum permissible grid voltage is 253V but inverters often measure several volts higher particularly when they are nearing maximum power - if this is reported to your DNO they should...
- Sun May 12, 2024 2:46 pm
- Forum: Customer/End User Help
- Topic: G8 inverter problems
- Replies: 21
- Views: 348
Re: G8 inverter problems
At 8kW I assume it’s a KH8 that has been installed ? That sounds very much like it is seeing either a high grid voltage or too high a current on one of the PV strings which results in an alarm that shuts down the generation - the inverter will then go through a mandatory wait time and then perform c...
- Sun May 12, 2024 11:51 am
- Forum: Inverter Hardware
- Topic: Upgrade battery and BMS firmware?
- Replies: 4
- Views: 163
Re: Upgrade battery and BMS firmware?
I'm afraid i've never come across any instructions for battery remote upgrade, probably best to email fox service for advice. I'd be grateful if you can post back what they say so that we'll know for next time.
- Sun May 12, 2024 11:12 am
- Forum: Battery Hardware
- Topic: HV25 vs HV2600?
- Replies: 5
- Views: 260
Re: HV25 vs HV2600?
There isn’t much difference on paper anymore - the HV25 used to have a lower cycle count and depth of discharge but for the past 12 months they have been pretty much in parity, they are exactly the same physical size but the battery structure internally is different and the MIra has slightly less ca...
- Sun May 12, 2024 11:06 am
- Forum: Firmware
- Topic: How to update foxess (S series G2)
- Replies: 7
- Views: 451
Re: How to update foxess (S series G2)
I have one fox ss1500 g2 Where i can get the last firmware? Now i have master version 1.20 It can be upgraded by inserting a USB stick into the socket on the bottom - you will need to contact your local Fox service office to get the latest files - the post above describes how you format the USB sti...
- Sun May 12, 2024 9:50 am
- Forum: Customer/End User Help
- Topic: Force charge option missing
- Replies: 4
- Views: 121
Re: Force charge option missing
Hi, you don't say which inverter this (H1 G2?) is or which app (or website) you are using as that will affect the answer - can you confirm those please. The original charge periods 1&2 are more than sufficient to charge your batteries on the low tariff rate - the scheduler (force charge/discharg...
- Sun May 12, 2024 9:11 am
- Forum: Mira HV25
- Topic: BMS dip switch
- Replies: 8
- Views: 1359
Re: BMS dip switch
Hi, I have just added a third HV2600 battery to my system. Followed the instructions, checked the voltage etc. set the dip switch to 1 Before adding the voltage was around 105v, after adding it went up to around 158 so there is a circuit. On the app the system is now displaying the higher voltage B...
- Fri May 10, 2024 12:56 pm
- Forum: Home Assistant
- Topic: H3 Inverter & ModBus help
- Replies: 19
- Views: 3076
Re: H3 Inverter & ModBus help
Hi everyone. Is it possible to use Fox Smart W Wifi stick as the only hardware to integrate FOX-ESS inverter H3-5.0-E with home assistant? I tried to do it but got stuck with comunication, after inserting the IP of this dongle... Is the extra hardware absolutely necessary or there is any way of int...
- Fri May 10, 2024 9:09 am
- Forum: Energy Stats App
- Topic: API Key is obfuscated??
- Replies: 4
- Views: 164
Re: API Key is obfuscated??
The moment you generate the key it isn't obfuscated, so you need to copy it then without changing screen or clicking on any other button - the moment you leave the screen and come back it will be obfuscated. I find it easier to use a desktop or laptop where you can see the full screen on the foxessc...
- Wed May 08, 2024 6:39 pm
- Forum: Customer/End User Help
- Topic: How to stop exporting to the grid please
- Replies: 9
- Views: 373
Re: How to stop exporting to the grid please
I’m not quite sure I understand the charge going to the grid, if you are generating solar power and the battery is full the solar would then be exported. I’ll start with the charge periods, if we get those set correctly we can then see if there are any problems. Using the old app you should set the ...
- Wed May 08, 2024 4:48 pm
- Forum: Hybrid (Solar + Battery)
- Topic: MODBUS on H1-5.0-E
- Replies: 13
- Views: 226
Re: MODBUS on H1-5.0-E
ok, for what it's worth be sure that your DHCP is set to disabled and I think you said you had checked the slave ID but whilst you are in the menu double check it's set to 247. Your modbus command looks correct, i'm quite surprised it doesn't respond ? Pins 3 (485B) & 4 (485A) are the correct pi...
- Wed May 08, 2024 3:18 pm
- Forum: Hybrid (Solar + Battery)
- Topic: MODBUS on H1-5.0-E
- Replies: 13
- Views: 226
Re: MODBUS on H1-5.0-E
A few things to look at, have you been using modbus direct over LAN?, if you have you must disable the ethernet port for the RS485 to respond. How are you sending the modbus request, using modpoll.exe ? and if so what is the command and register location you are writing to. If you are using modpoll....
- Wed May 08, 2024 2:52 pm
- Forum: Energy Stats App
- Topic: Energy Stats App failing to load data - Error message
- Replies: 6
- Views: 176
Re: Energy Stats App failing to load data - Error message
It’s not the app, it’s the Fox servers that are having issues - it has been reported to Fox (both UK & China) and they are looking into it.
- Wed May 08, 2024 8:49 am
- Forum: Customer/End User Help
- Topic: About charging and discharging batteries
- Replies: 39
- Views: 4502
Re: About charging and discharging batteries
Can you tell me with Modbus addresses i need to work with to do the trick with 'Force Discharge' and 'Force Charge'. I have a Inverter model Kuara 8.0-3-H Master 1.95 and Manager 1.77 Have a read of this thread, it should help you with this https://github.com/nathanmarlor/foxess_modbus/discussions/...
- Tue May 07, 2024 4:06 pm
- Forum: Customer/End User Help
- Topic: Fox Cloud App - Device Statistics (daily income)
- Replies: 1
- Views: 79
Re: Fox Cloud App - Device Statistics (daily income)
The income stats for the original app are almost meaningless, rather than use your export * export rate, it uses the total yield * export rate. The total yield is all of the output the inverter has done either from solar or battery. So definitely trust your smart meter / Octopus on that one. You wou...
- Tue May 07, 2024 9:21 am
- Forum: Hybrid (Solar + Battery)
- Topic: Modbus Daily and Total reg data screwed up from 6th May.
- Replies: 2
- Views: 86
Re: Modbus Daily and Total reg data screwed up from 6th May.
I've seen inverter registers get corrupted following a firmware update, where it corrupts the top bits in the generation totals register, but it's usually the total yield register it happens to and this looks to be different - is this the inverters 'total' charge/discharge registers, they are 'uint3...
- Mon May 06, 2024 1:17 pm
- Forum: Customer/End User Help
- Topic: PV output clipping during strategy set forced charge
- Replies: 4
- Views: 256
Re: PV output clipping during strategy set forced charge
Do you know if this been addressed by firmware update(s) yet? I have Manager 1.70 on H1-5.0-E in the UK. It works okay to use the 'old' grid charge periods but switching between these and the otherwise more flexible Mode Scheduler is cumbersome. Since going over to Octopus Agile I sometimes find my...
- Sun May 05, 2024 9:28 pm
- Forum: Customer/End User Help
- Topic: System offline
- Replies: 3
- Views: 111
Re: System offline
Sounds like you’ve done most of the obvious things, if you haven’t already I would restart you router as that sounds like it’s blocking the connection - after the restart wait a couple of minutes and look at the red light on the dongle, if it’s flashing red slowly it has connected and you should be ...
- Sun May 05, 2024 3:11 pm
- Forum: Customer/End User Help
- Topic: Error codes 26 , 27 … (sorry for repeating this post )
- Replies: 7
- Views: 2606
Re: Error codes 26 , 27
Had this error several times this week. During the night, occupied and unoccupied, ie house load and no load. Each times it trips the consumer unit. Any ideas? . It's the consumer unit tripping that is causing the error (i.e. the grid voltage is lost), on a new install this is sometimes because the...