Re: EQ4800 Export Limit via FoxCloud app, restricted??
This setting is regulated in most countries and was exposed to Fox users for a brief time between app versions 2.1 and 2.2.3. These settings should only be changed by installers, which is why they were removed from end-user profiles recently.
I understand some users found it useful, but Fox is ...
I understand some users found it useful, but Fox is ...
Sun Mar 15, 2026 5:39 pm
Re: H3-12.0-Smart Modbus Connection
That is correct. I actually did this while being not at home at all ;). No additionally device has been connected to the inverter. The only thing I needed someone at home to check was the inverters slave ID but no change was needed since the slave ID was already at 247.
I am currently trying ...
Tue Mar 03, 2026 9:01 pm
Re: Home Assistant with Home Assistant Green
As you have the H3 Smart, you only need a device to host Home Assistant. The Home Assistant Green is a great choice.
As your inverter has a built in modbus server you don't need any extra hardware. Simply enter the inverters ip address into the foxess modbus integration and it will all work.
I demo ...
As your inverter has a built in modbus server you don't need any extra hardware. Simply enter the inverters ip address into the foxess modbus integration and it will all work.
I demo ...
Sat Feb 28, 2026 2:12 pm
Re: How to export data from the Charger
What model charger?
Wed Feb 25, 2026 5:45 pm
Re: FoxESS system exporting to grid without PV production
You'll want your installer to update your firmware and then set the grid compensation setting.
I cover it here:
I cover it here:
Tue Feb 24, 2026 10:03 pm
Re: AC Coupling on the backup side
Hello,
Not recommended, if you do that, you'll find the EPS will trip with overload if you solar generates more than your house load while off grid as it can't be clipped.
If you want solar generation during a powercut you should dc couple it.
Not recommended, if you do that, you'll find the EPS will trip with overload if you solar generates more than your house load while off grid as it can't be clipped.
If you want solar generation during a powercut you should dc couple it.
Tue Feb 24, 2026 10:00 pm
Re: Odd behavior with new AC coupled GoodWe + FoxESS Smart H3 AC3 15
2.5kW isn't much power, honestly
Tue Feb 24, 2026 9:55 pm
Re: My manage battery charging has disappeared
You'll need to move to the new way called Mode Schedules. I made a video how to use it here
Fri Feb 20, 2026 9:21 am
Re: Octopus Agile -registering on the Fox App
Account number and API key in those boxes
Fri Feb 20, 2026 9:17 am
Re: New installation - Mode scheduler not visible?
I made this video to help, don't use the simply two slot settings as these are being phased out. Make sure you use the mode scheduler.
Thu Feb 19, 2026 11:55 am
Re: Adjusting min state of charge
try setting the backup reserve to 90%, hit save, then lower the minsoc to 10%, hit save, then lower the backup level to 20-30% and hit save.
Sun Feb 08, 2026 11:02 am
Re: Add Fox ESS Charger to existing plant
It needs to be added to your existing site to appear correctly.
Sat Feb 07, 2026 9:30 pm
Re: Is this installation compliant?
Yes, fox ess K series requires a 500mm gap. That is going to cause a lack of ventilation, I suspect.
page 11 of the install manaual
page 11 of the install manaual
Thu Feb 05, 2026 10:22 am
Re: Battery charge current limited to 5A
yeh, it continues to derate down to low single figures when the battery stops responding.
Mon Feb 02, 2026 12:24 pm
Re: Tibber - Cant connect it to app
I don't believe it's supported at this time.
Mon Feb 02, 2026 11:23 am
Re: Battery charge current limited to 5A
You need to be looking at the bms mincell temp not the battery temp as that is the bms which is normally warm. The bms charge limits are set from the mincell temp value. Anything under 12c will start limiting the charge rate.
Use the foxcloud2 to report on your mincell temp as I show here:
https ...
Use the foxcloud2 to report on your mincell temp as I show here:
https ...
Mon Feb 02, 2026 11:21 am
Re: Selling To Grid When Battery Is Full
I bet your export limit is set to 0 watts or you've got your system in force charge mode instead of self use.
Mon Feb 02, 2026 11:19 am
Re: Negative Revenue
can you post a screen shot of the energy flow page so I can confirm how your system is setup.
The short version is the inverter will be recording it's generation without any additional action.
The short version is the inverter will be recording it's generation without any additional action.
Thu Jan 29, 2026 9:24 am
Re: Forced discharge not reverting to Self Use
I was chatting with my fox ess contacts today and they've asked me for more details and they'll look into. hoping to get this fixed asap
Fri Jan 23, 2026 4:42 pm
Re: Fox EVO 10-8-H modbus registers
Hi Brian,
all changes I made to the original modbus integration are here:
https://github.com/AdamNewberry/foxess_modbus_EVO/tree/main
i installed it via HA manually from my git fork download.
it went through all the normal setup steps like the official hacs version from nathan.
Adam
Are ...
Fri Jan 23, 2026 2:15 pm
Re: Lower my Battery Reserve Capacity to 10%?
I have a Home Assistant automation that jacks up my minsoc from 10% when there is forecasted bad or stormy weather. That way, I can use the full battery range most of the time, but on days when the risk of a power cut is increased, I have an extra reserve. Has worked well for me for years.
Fri Jan 23, 2026 9:01 am
Re: Fox ESS Octopus Smart Tariff Integration Beta Testers (Octopus Intelligent Flux)
Currently, invite only to this new tariff.
Fri Jan 23, 2026 8:58 am
Re: Which energy supplier do I choose?
Morning,
I'm a big fan of Octopus Go, which is a dumb (not smart requires you to set a force charge schedule) 5 hrs of 8.5p per night for the ev and whole house or the intelligent go, which is 6 hours at 7p for house and ev plus random additional cheap slots when the grid is green and cheap but ...
I'm a big fan of Octopus Go, which is a dumb (not smart requires you to set a force charge schedule) 5 hrs of 8.5p per night for the ev and whole house or the intelligent go, which is 6 hours at 7p for house and ev plus random additional cheap slots when the grid is green and cheap but ...
Mon Jan 19, 2026 11:10 am
Re: Running old schedule after firmware update
I've seen a number of reports of this also. so agree a one time manual check and reapply seems to solve it.
Sat Jan 17, 2026 12:48 pm
Fox ESS Evo User Manual
Fox ESS Evo User Manual
Tue Jan 13, 2026 6:53 pm