Search found 6 matches
- Fri Oct 06, 2023 8:06 pm
- Forum: Customer/End User Help
- Topic: Battery not discharging
- Replies: 5
- Views: 1767
Re: Battery not discharging
I have eventually fixed the problem which was simply there was no CT meter connected. In retrospect it was obvious. But when you've inherited a 2 year old system supposedly installed by a professional company and in working condition, I frankly cannot believe such a basic step had been missed and ...
- Sun Oct 01, 2023 7:17 pm
- Forum: HV2600
- Topic: BMS unresponsive to house demand
- Replies: 26
- Views: 9577
Re: BMS unresponsive to house demand
Thanks for your reply. There definitely is no CT clamp or meter installed, this must be the problem. Unbelievable the installer didn't do this originally and the previous owners didn't realise, the system is 2 years old now!
- Sat Sep 30, 2023 11:55 am
- Forum: Customer/End User Help
- Topic: Self-use , but PV prioritizing export and not charging battery
- Replies: 3
- Views: 1105
Re: Self-use , but PV prioritizing export and not charging battery
Is your battery max charge set to 90% perhaps? It's normal to limit charging to e.g. 90 or 95% to prolong battery life. Its in the battery settings. If your systems firmware was recently updated (mine was last week i think) it also resets some of the settings, so even if it wasn't set to 90% before ...
- Thu Sep 28, 2023 2:21 pm
- Forum: Customer/End User Help
- Topic: Battery not discharging
- Replies: 5
- Views: 1767
Re: Battery not discharging
Hi No I've still not got to the bottom of it. The firmware has just been updated (I'm not sure how) but doesn't seem to have helped. And my charging times are already set to 00:00 unfortunately, tried that before! But thanks. The only thing that I've found that seems odd is there doesn't seem to be ...
- Mon Jul 31, 2023 2:00 pm
- Forum: HV2600
- Topic: BMS unresponsive to house demand
- Replies: 26
- Views: 9577
Re: BMS unresponsive to house demand
Hi. You say the issue was your CT clamp in the end, is a CT clamp mandatory for the system to work properly? My system which has never worked since I moved in a few months ago (battery doesnt discharge, just sits there fully charged), does not seem to have a CT clamp anywhere?? And the setting is ...
- Mon Jul 31, 2023 12:53 pm
- Forum: Customer/End User Help
- Topic: Battery not discharging
- Replies: 5
- Views: 1767
Battery not discharging
Hi all I've recently bought a house with an installed 6kwh PV system with Fox H1 5kw inverter, and 2x HV2600 batteries. The issue I am having is the battery will not discharge, no matter what setting I use. It is sat at ~98% at all times and according to the real time data just using a constant ...