Ok sorry, I should have followed your link, I assumed it was the forthcoming Power cube that is an inverter and 'hub' built in together and then sits on top of an ECS(EQ) battery stack. I haven't heard anything about the Hub being released here in the UK, and I would have thought with our regulatory ...
by Dave Foster
Thu Oct 31, 2024 4:00 pm
Forum: EPS - Emergency Power Supply (Battery Backup)
Topic: EPS Setup for Whole House Supply
Replies: 13
Views: 6697

Re: EPS Setup for Whole House Supply

Just going through the spec and install of PV, H1-6.0-E-G2, EP11 and looking for whole house EPS. I saw the US have a great device similar to some other manufacturers the 'FOX HUB G2', it seems like this is coming to the UK which is fantastic news, but anyone got more info and when this is likely ...
by Dave Foster
Thu Oct 31, 2024 10:17 am
Forum: Customer/End User Help
Topic: Melted battery connector
Replies: 1
Views: 121

Re: Melted battery connector

You are lucky that you noticed it, and looking at the picture it appears that the front battery connector hadn't been pushed all the way home as it would have been held by the clips like the rear connector - if the connection was then loose, there would have been arcing when high loads switch in or ...
by Dave Foster
Wed Oct 30, 2024 3:21 pm
Forum: Customer/End User Help
Topic: KH10.5 Intrinsic Design Capacity (IDC)
Replies: 1
Views: 153

Re: KH10.5 Intrinsic Design Capacity (IDC)

Hi, see here https://www.ena-eng.org/gen-ttr/Index?A ... tab=search, its listed as it's 'Registered Capacity' which is 10.5kW
by Dave Foster
Wed Oct 30, 2024 9:05 am
Forum: Customer/End User Help
Topic: T15 in parallel
Replies: 3
Views: 157

Re: T15 in parallel

If you only have the one RS485 then it doesn't support parallel running - you may still be able to wire up the system in such a way that you have 2 inverters on separate circuits but it is not ideal - it still would be worth checking your inverter serial number with you local Fox service so you know ...
by Dave Foster
Wed Oct 30, 2024 8:46 am
Forum: Customer/End User Help
Topic: T15 in parallel
Replies: 3
Views: 157

Re: T15 in parallel

The later T series inverters have a 3rd RS485 port for connecting themselves in parallel - you will need to email your local Fox service with your inverter serial number and get them to confirm you have a T series that will support this function.
by Dave Foster
Tue Oct 29, 2024 8:56 am
Forum: Pre-sales Questions
Topic: H1 G2 5kw hybrid inverter noise
Replies: 1
Views: 411

Re: H1 G2 5kw hybrid inverter noise

If you install outside you’ll need some kind of cover to avoid direct weather contact and preferably insulation around the battery in winter - some people build small wooden enclosures with ventilation and they add insulation in winter - works well if you have the space and time. Back to your o ...
by Dave Foster
Sun Oct 27, 2024 9:17 pm
Forum: Customer/End User Help
Topic: Battery discharging to 10% in an hour
Replies: 18
Views: 683

Re: Battery discharging to 10% in an hour

No I think it’s best to leave it the way it is, the charge periods can only charge or hold the discharge, whereas the mode scheduler can really change the behaviour as well as force the batteries to discharge. There’s no obvious load at 5am so hopefully a few days of running like this will give you s ...
by Dave Foster
Sun Oct 27, 2024 8:35 pm
Forum: Customer/End User Help
Topic: Battery discharging to 10% in an hour
Replies: 18
Views: 683

Re: Battery discharging to 10% in an hour

I can’t see much wrong with that trace, the load appears to be showing correctly which it wouldn’t if the CT’s were the wrong way round and the battery is taking charge when there is spare solar and you are exporting (a little) as well. It is possible that one CT phase is wrong but i’m not seeing evi ...
by Dave Foster
Sun Oct 27, 2024 5:16 pm
Forum: Customer/End User Help
Topic: Battery discharging to 10% in an hour
Replies: 18
Views: 683

Re: Battery discharging to 10% in an hour

On that first image, when you swipe left can you scroll up the page and you should find a graph at the bottom of the page that looks like this -
IMG_8259.png
That will be really useful to see as it shows your house load, solar, grid use and battery together
by Dave Foster
Sun Oct 27, 2024 3:31 pm
Forum: Customer/End User Help
Topic: Battery discharging to 10% in an hour
Replies: 18
Views: 683

Re: Battery discharging to 10% in an hour

You’ve set it to charge the battery between 3 & 5am, and then not to use the battery at all from 5 til 7 which will stop it discharging - but the big question remains why was the battery discharging after 5am when there is no house load, that is usually a sign of reversed CT clamp if there was no l ...
by Dave Foster
Sat Oct 26, 2024 2:51 pm
Forum: Customer/End User Help
Topic: Battery discharging to 10% in an hour
Replies: 18
Views: 683

Re: Battery discharging to 10% in an hour

Ahh ok, it's a 3 phase house - basically the same principle but you have 3 CT clamps that measure the load on each phase. It could be one CT clamp, 2 or all 3 that are the wrong way round, so yes best to call your installer and they can test each phase to make sure it is reading correct. Once the CT ...
by Dave Foster
Sat Oct 26, 2024 2:02 pm
Forum: Customer/End User Help
Topic: Battery discharging to 10% in an hour
Replies: 18
Views: 683

Re: Battery discharging to 10% in an hour

Yes that looks very much like the CT clamp is pointing in the wrong direction - you have 2 options, call the installer and ask them to rectify it, or you could locate and turn the clamp around yourself, it's not too difficult, If you post a photo of your meter cupboard i'll confirm where it is - the ...
by Dave Foster
Sat Oct 26, 2024 1:16 pm
Forum: Customer/End User Help
Topic: Battery discharging to 10% in an hour
Replies: 18
Views: 683

Re: Battery discharging to 10% in an hour

You’ve not said which system it is, is it a solar inverter with an add on AC battery, or is it a hybrid with solar and (now) batteries?. I really need to see your energy flow screen from either the app or website, but it sounds very much like the CT clamp has been placed in the wrong orientation - ...
by Dave Foster
Fri Oct 25, 2024 12:45 pm
Forum: Customer/End User Help
Topic: Trickle charge vs Force charge
Replies: 1
Views: 360

Re: Trickle charge vs Force charge

The BMS is quite good at managing things, but a few people (including me) do some kind of battery management - usually using home assistant which does all the maths for you and can control it precisely. I've found over time that you can charge at full power but if you allow it to charge at 4A (or 5A ...
by Dave Foster
Thu Oct 24, 2024 8:26 am
Forum: Customer/End User Help
Topic: Hoe to schedule batteries to not discharge
Replies: 9
Views: 1354

Re: Hoe to schedule batteries to not discharge

Hi, I had an install recently and foresaw the issue you have about the EV battery charging only from the grid. I told my installer to add an additional Henley block so that the system is wired that the EV battery is connected to the grid before the battery connection and load monitoring CT for the ...
by Dave Foster
Wed Oct 23, 2024 4:24 pm
Forum: Customer/End User Help
Topic: Missing statistics monthly and annual chart
Replies: 1
Views: 496

Re: Missing statistics monthly and annual chart

The statistics you have mentioned don't get populated for inverters that are not hybrids with energy storage - i'm not entirely sure why, but that comes direct from Fox themselves.
by Dave Foster
Mon Oct 21, 2024 2:32 pm
Forum: Battery Hardware
Topic: EP11 - LFP or Li-Ion?
Replies: 2
Views: 949

Re: EP11 - LFP or Li-Ion?

They are LifePo4 (LFP) the label says Li-ion as that is their category, it is a type of Lithium Ion battery but they are unquestionably Lithium Ion Phosphate.
by Dave Foster
Sat Oct 19, 2024 11:43 am
Forum: Hybrid (Solar + Battery)
Topic: Inverter restarting when exporting
Replies: 3
Views: 2196

Re: Inverter restarting when exporting

That suggests your local grid frequency / voltage are outside of the safety params and are being exceeded when you are exporting. Use the Fox website and in the lower graph select the params RVolt and RFreq for a day where this has happened - if you could post them here so we can see the traces. Can ...
by Dave Foster
Fri Oct 18, 2024 12:17 pm
Forum: Customer/End User Help
Topic: Inverter F3600 + meter DDSU666 wiring and configuration
Replies: 2
Views: 802

Re: Inverter F3600 + meter DDSU666 wiring and configuration

Just to double check you, you said pins 23, 24 - I think you meant 24(A) & 25(B) where 24 goes to pin 4 on the meter and pin 25 goes to pin 3

You need to make sure you have set the meter up as modbus, id 001 and 9600, N, 8, 1
by Dave Foster
Thu Oct 17, 2024 12:30 pm
Forum: Welcome space / Install gallery
Topic: Hello from the East Midlands!
Replies: 9
Views: 2413

Re: Hello from the East Midlands!

The app reports the lowest cell voltage, whereas modbus is reporting the BMS temperature which will be 5-10C higher. The H1 (Gen 2) & KH inverters don’t currently report the BMS low and high cell temps, but this might arrive in a future release as Fox are changing the modbus registers to align to t ...
by Dave Foster
Wed Oct 16, 2024 3:38 pm
Forum: Video Guides
Topic: FoxESS Octopus Agile Integration
Replies: 3
Views: 2643

Re: FoxESS Octopus Agile Integration

On the update call last week, Fox said that for most users it works ok, but there are some (as yet reasons unknown) where there are problems - they have asked for those users that are affected and can provide specific details (i.e. not just it doesn't work) - to contact them on service.uk@fox-ess ...
by Dave Foster
Tue Oct 15, 2024 9:04 am
Forum: Energy Stats App
Topic: Switched to 2.5ghz WiFi - broke Energy Stats?
Replies: 4
Views: 1767

Re: Switched to 2.5ghz WiFi - broke Energy Stats?

It came back approx 2.25am, all working normally now - so you're good to go.
by Dave Foster
Mon Oct 14, 2024 7:24 pm
Forum: Energy Stats App
Topic: Switched to 2.5ghz WiFi - broke Energy Stats?
Replies: 4
Views: 1767

Re: Switched to 2.5ghz WiFi - broke Energy Stats?

It’s nothing you’ve done - the Fox OpenAPI is down completely at the moment for all users - probably best to leave it til tomorrow morning and hopefully it’ll be back up again.
by Dave Foster
Mon Oct 14, 2024 9:01 am
Forum: Welcome space / Install gallery
Topic: Hello from the East Midlands!
Replies: 9
Views: 2413

Re: Hello from the East Midlands!

Nice that should do the trick.... the world would be lost without duct tape ;)