Search found 8 matches
- Sat Jul 01, 2023 12:22 am
- Forum: Customer/End User Help
- Topic: Second battery stack
- Replies: 6
- Views: 2615
Re: Second battery stack
Hi Again I would stay away from doing this. Again please follow the installation instructions when. Installing these. Might seem like a bore but don’t install as per the instructions then your warranty void. I am sick of seeing poor installs of solar systems the industry’s full of you tube ins ...
- Mon Jun 19, 2023 7:53 pm
- Forum: Customer/End User Help
- Topic: Second battery stack
- Replies: 6
- Views: 2615
Re: Second battery stack
Hi Battery leads are the same so will fit. As for the second stack I would start a separate stack I would be more concerned about the weight on the brackets (bottom set)and probably think this is why you should only stack 4 max. If bracket gave way then you could have a bigger problem with damaged ...
- Sun Jun 04, 2023 12:02 am
- Forum: Customer/End User Help
- Topic: no energy export to grid
- Replies: 4
- Views: 1598
Re: no energy export to grid
Hi
Might be worth checking that the inverter is set to on grid in the menu it might be set to off grid. Also check the work mode is set to self use
Cheers
Might be worth checking that the inverter is set to on grid in the menu it might be set to off grid. Also check the work mode is set to self use
Cheers
- Sun May 28, 2023 12:36 am
- Forum: Mira HV25
- Topic: H3 6KW inverter & 3 x hv25 batteries
- Replies: 2
- Views: 2261
Re: H3 6KW inverter & 3 x hv25 batteries
Hi
Forgot to mention
Shut the system down. Reset them switches on the batteries to off (down) restart the system. It will address the batteries during startup
This might sort it for you
Not to sure why your installer has used these switch’s.
Cheers
Forgot to mention
Shut the system down. Reset them switches on the batteries to off (down) restart the system. It will address the batteries during startup
This might sort it for you
Not to sure why your installer has used these switch’s.
Cheers
- Sun May 28, 2023 12:25 am
- Forum: Mira HV25
- Topic: H3 6KW inverter & 3 x hv25 batteries
- Replies: 2
- Views: 2261
Re: H3 6KW inverter & 3 x hv25 batteries
Hi
Don’t understand why your installer has addressed your batteries like this. Is it a fox BMS?
Cheers
Don’t understand why your installer has addressed your batteries like this. Is it a fox BMS?
Cheers
- Wed May 24, 2023 4:25 pm
- Forum: Battery Hardware
- Topic: Adding Batteries
- Replies: 2
- Views: 2346
Re: Adding Batteries
Hi. Just make sure you get fox or your installer to update all the firmware to the same versions on you batteries and update the BMS firmware too or the system will not see the capacity of the batteries. Just done some and charging and discharging don’t fix the issue. Need all firmware the same. Fox ...
- Sun May 21, 2023 10:15 am
- Forum: Mira HV25
- Topic: Mira Hv25 Battery output
- Replies: 4
- Views: 2743
Re: Mira Hv25 Battery output
Hi You restricted by the output of your inverter normally 3.68kw in most cases. When using oven and hob you will find oven will draw 2.5kw and an average hob ring will draw 1.5kw so 4kw. 3.68kw coming from the inverter and the other 300w coming from the grid. Don’t know what size inverter you have. ...
- Sat May 20, 2023 8:09 pm
- Forum: HV2600
- Topic: Adding battery confusion
- Replies: 2
- Views: 2414
Re: Adding battery confusion
Hi All current version D batteries for sale are V1 batteries so no need to mess on with changing the BMS If your current one are D then they will work but. Also make sure once you’re installed them that your installer or fox update all the batteries to the same firmware version and update the f ...