Search found 20 matches

by Judy01
Thu Oct 03, 2024 4:42 pm
Forum: AC (Battery Only Inverters)
Topic: AC Chargers with existing PV array
Replies: 8
Views: 3036

Re: AC Chargers with existing PV array

Hi I checked my analysed data, my peak usage does not exceed 3KW but given the price difference between 3 - 5 KW, i get the advantages of servicing a higher demand when needed. I have now talked with an installer. He explained that the new AC Charger and existing Grid tied Inverter will both need to ...
by Judy01
Thu Oct 03, 2024 4:31 pm
Forum: Customer/End User Help
Topic: Fox ess hybrid 10.5 wifi problems
Replies: 13
Views: 5143

Re: Fox ess hybrid 10.5 wifi problems

Hi Dave ... thought I would report back.. As mentioned splitting my router to broadcast 2G and 5G created a very poor network service. So I attempted to synchronise again using the Wifi Extender unfortunately the Dongle still would not accept a synchronised 2G, 5G service. I disconnected the Wifi ...
by Judy01
Mon Sep 30, 2024 9:44 pm
Forum: AC (Battery Only Inverters)
Topic: AC Chargers with existing PV array
Replies: 8
Views: 3036

Re: AC Chargers with existing PV array

Thanks Dave

LOL I see what you mean - consider likely house load peak ! That is a very good point..
The price difference between 3 and 5kW isn't much anyway..
Really appreciated...

Judy
by Judy01
Mon Sep 30, 2024 2:16 pm
Forum: AC (Battery Only Inverters)
Topic: AC Chargers with existing PV array
Replies: 8
Views: 3036

Re: AC Chargers with existing PV array

Thank you Dave Yes Solar produced this year is 1700. Estimated usage for current year 1000KW taking into consideration offset cost to house load needs.. Thanks for clarifying my considerations.. I am on Octopus 12mths Fixed Outgoing 15p KwH. I think it's worth getting a bigger batter if only to ...
by Judy01
Sun Sep 29, 2024 10:35 pm
Forum: AC (Battery Only Inverters)
Topic: AC Chargers with existing PV array
Replies: 8
Views: 3036

Re: AC Chargers with existing PV array

Hi My current 2kW PV Fox ESS grid tied system currently has no battery backup. The system has been installed for a year now and has managed to produce 17kwh, thankfully my usage is 14kwh annually, so installing batteries to eliminate this bill altogether might be a good idea! I am interested AC ...
by Judy01
Wed Sep 04, 2024 6:05 pm
Forum: Customer/End User Help
Topic: Fox ess hybrid 10.5 wifi problems
Replies: 13
Views: 5143

Re: Fox ess hybrid 10.5 wifi problems


Yes, absolutely you don't have to change anything on the router other than press the WPS button to link the extender :)
Brill! Thank you Dave :D
by Judy01
Wed Sep 04, 2024 8:11 am
Forum: Customer/End User Help
Topic: Fox ess hybrid 10.5 wifi problems
Replies: 13
Views: 5143

Re: Fox ess hybrid 10.5 wifi problems

Hi Dave Thanks for your speedy response. So double checking, at the mo I split my router l to create a dedicated 2G snd 5G network, creating havoc with the service. I am hoping the extender solution will eliminate the need to do that. Is that correct? Really appreciated thanks.. Judy FoxESS S2000 ...
by Judy01
Tue Sep 03, 2024 4:52 pm
Forum: Customer/End User Help
Topic: Fox ess hybrid 10.5 wifi problems
Replies: 13
Views: 5143

Re: Fox ess hybrid 10.5 wifi problems

The only other thing I can think of is , some it gets confused with some routers / extenders as they have both wifi bands (2.4Ghz & 5Ghz) on the same SSID - the datalogger can only connect to 2.4Ghz - if possible can you try and disable the 5Ghz band or rename it so it has a different SSID to the 2 ...
by Judy01
Mon May 13, 2024 9:49 pm
Forum: Mobile App Help
Topic: help understanding app overview page
Replies: 4
Views: 1774

Re: help understanding app overview page

Hi Dave
V2 app. I appreciate your explanation.
Thank you
Judy
by Judy01
Mon May 13, 2024 8:04 pm
Forum: Mobile App Help
Topic: help understanding app overview page
Replies: 4
Views: 1774

help understanding app overview page

Hi All Time of reading is 19:52, my app reading : load 11kw, PV 54w and grid 69w. I am a little confused,, if the house load is only 0.11kw, why am I drawing 69w from the grid. Confused.com Also how do I get a total export read from this app, does this feature exist? Appreciate your help. Judy
by Judy01
Sat Oct 28, 2023 1:31 pm
Forum: Customer/End User Help
Topic: -0.5kw dip in output power for 30m every 3hrs
Replies: 6
Views: 1757

Re: -0.5kw dip in output power for 30m every 3hrs

Thank you for your very clear explanation.

:D
by Judy01
Fri Oct 27, 2023 7:42 pm
Forum: Customer/End User Help
Topic: -0.5kw dip in output power for 30m every 3hrs
Replies: 6
Views: 1757

Re: dip in load power

Just recently had my inverter upgraded from 1500kW to 2kW - believed it to be undersized. I have been recording the graphs, two of which is attached and noticed I am now getting negative zero load readings - which was not the case before. Can anyone explain what could be causing this.. and is it ...
by Judy01
Fri Oct 06, 2023 7:21 pm
Forum: Mobile App Help
Topic: Load Power readings at zero
Replies: 7
Views: 2418

Re: Load Power readings at zero

I appreciate your input. Since I have no response from my installers, I am now writing to Fox. I need to establish cause, as one week letter and still no graph indication that solar energy is being used by the home! In the absence of a response I think it is the installers. I am sure there must be a ...
by Judy01
Tue Oct 03, 2023 7:47 pm
Forum: Mobile App Help
Topic: Load Power readings at zero
Replies: 7
Views: 2418

Re: Load Power readings at zero

Thanks for your response... You can see from the graph, it appears the inverter is unable to hold its own peak of managing solar energy at 2500. Panels are 415kw (=2.07kw) I am told annual est. Solar generation 1848kw ..If the decision to undersize was based on efficiency would we not consider ...
by Judy01
Mon Oct 02, 2023 11:50 pm
Forum: Mobile App Help
Topic: Load Power readings at zero
Replies: 7
Views: 2418

Re: Load Power readings at zero

Thanks for your reply which is appreciated. I have 5 panels. I do not yet have a smart metre awaiting an install Is there a good reason why an installer would undersize the inverter? I can now see what the disadvantages are. Any thoughts on the dip in solar generation - the panels are all facing the ...
by Judy01
Sun Oct 01, 2023 1:50 pm
Forum: Mobile App Help
Topic: Error - server with the specified hostname could not be found
Replies: 10
Views: 2765

Re: Error - server with the specified hostname could not be found

Thanks for your reply. No there are no odd setting configurations on my phone, just a robust virus guard and VPN and once these are switched off there is no reason why the app should not work.. Never mind. the installer explained the App would not work on 5Ghz wifi, so naturally I assumed ...
by Judy01
Sat Sep 30, 2023 8:14 pm
Forum: Mobile App Help
Topic: Error - server with the specified hostname could not be found
Replies: 10
Views: 2765

Re: Error - server with the specified hostname could not be found

Found a very old phone Android version 8 on which the Foxess cloud app actually worked!
Appears the issue is not with my phone, the cloud app is not developed to work with anything above Android version 8 it appears.
If otherwise, please explain
by Judy01
Sat Sep 30, 2023 4:22 pm
Forum: Mobile App Help
Topic: Load Power readings at zero
Replies: 7
Views: 2418

Load Power readings at zero

My S Series1500 was installed a couple of days ago. I was advised that the house load power should be distributed for my use before any export of excess to the Grid. It was explained the feed in power and output power, which appear to be an equally shared distribution of power, meant that the house ...
by Judy01
Sat Sep 30, 2023 3:57 pm
Forum: Mobile App Help
Topic: Error - server with the specified hostname could not be found
Replies: 10
Views: 2765

Re: Error - server with the specified hostname could not be found

Thanks for your response, no I have not been able to access the url you provided - please see attachment.
VPN is off..
by Judy01
Thu Sep 28, 2023 7:59 pm
Forum: Mobile App Help
Topic: Error - server with the specified hostname could not be found
Replies: 10
Views: 2765

Re: Error - server with the specified hostname could not be found

Hi I am getting a similar or the same error message ' unable to resolve host 'www.foxesscloud.com' no address associated with hostname. I have turned off my mobile VPN but still unable to connect using my android phone. Would appreciate some help, thanks in advance. PV 2Kw Fox Grid inverter S Series ...