Exactly the same response for me today G4RNI. Thanks Martin Rimmer.
Phil
Search found 5 matches
- Wed Mar 29, 2023 4:40 pm
- Forum: HV2600
- Topic: BMS V2 with mixed v1/v2 batteries - Solution to persistent BMS alarms.
- Replies: 15
- Views: 12443
- Sat Mar 18, 2023 4:32 pm
- Forum: HV2600
- Topic: Force Discharge to Grid
- Replies: 0
- Views: 2354
Force Discharge to Grid
I noticed that this topic was aired last November and Will stated that most systems do not have this function. I have just seen a Youtube video of the new Octopus Flux tariff which allows discharge to the grid during the peak period of 1600 to 1900 and pays 47p/kWh during the 3 hours. There must be ...
- Mon Dec 12, 2022 3:56 pm
- Forum: HV2600
- Topic: HV2600 Manual
- Replies: 4
- Views: 2520
Re: HV2600 Manual
For Information: I have just fitted the V2.0 BMS free issue from FOX and the two new V2.0 HV2600's. Spoke to Matt at FOX who told me that the two new V2.0 battery modules MUST be the first modules wired AFTER the BMS OR THE ASSEMBLY WILL NOT WORK (ie if the older Version C batteries were the ones ...
- Thu Dec 01, 2022 11:01 am
- Forum: HV2600
- Topic: HV2600 Manual
- Replies: 4
- Views: 2520
Re: HV2600 Manual
Many thanks.
- Fri Nov 25, 2022 10:00 am
- Forum: HV2600
- Topic: HV2600 Manual
- Replies: 4
- Views: 2520
Re: HV2600 Manual
Hi Will I presume this is a newer version of the manual than the one that came with my new V2.0 HV2600's received last week? The manual version number that came with each of the NEW V2.0 batteries is V1.0, yours is V3.0! The 'slightly' disturbing thing is that on pages 6 and 7 the pin configurations ...