It turned out that the new comms data cable (the short interconnect one) was faulty.
All working now.
Search found 10 matches
- Thu Jul 04, 2024 1:18 pm
- Forum: Customer/End User Help
- Topic: Module addressing failed problem
- Replies: 10
- Views: 1208
- Tue Jun 25, 2024 7:10 pm
- Forum: Customer/End User Help
- Topic: Module addressing failed problem
- Replies: 10
- Views: 1208
Re: Module addressing failed problem
Do we know the latest Firmware ver for BMS and batteries?
Mine showing BMS as ver 1.004 but I was informed are being updated to 1.14 if I heard correctly.
Thanks
Mine showing BMS as ver 1.004 but I was informed are being updated to 1.14 if I heard correctly.
Thanks
- Tue Jun 25, 2024 11:10 am
- Forum: Customer/End User Help
- Topic: Module addressing failed problem
- Replies: 10
- Views: 1208
Re: Module addressing failed problem
Many thanks Dave. I appreciate your kind input.
- Tue Jun 25, 2024 8:03 am
- Forum: Customer/End User Help
- Topic: Module addressing failed problem
- Replies: 10
- Views: 1208
Re: Module addressing failed problem
PS FoxCloud 2.0 battery page shows Version_BMS 1.004 It only lists master and three slavers. The serial number for the new (fourth)battery isn’t listed And the inverter page shows Version_Master 1.65 Version_Slaver 1.02 Version_ARM 1.74 Are these in need of update? I have my fingers crossed that a f ...
- Tue Jun 25, 2024 7:34 am
- Forum: Customer/End User Help
- Topic: Module addressing failed problem
- Replies: 10
- Views: 1208
Re: Module addressing failed problem
Thank you,
Photo attached..
I have carefully checked and the addr dip switches all have the on label correct orientation.
I have raised a support ticket to request a check / firmware upgrade.
Photo attached..
I have carefully checked and the addr dip switches all have the on label correct orientation.
I have raised a support ticket to request a check / firmware upgrade.
- Sun Jun 23, 2024 12:38 pm
- Forum: HV2600
- Topic: Installed version 2 batteries but not working.
- Replies: 5
- Views: 2909
Re: Installed version 2 batteries but not working.
Jason Feeky - did you eventually resolve your problem? What was the issue eventually identified / the solution?
- Sun Jun 23, 2024 5:49 am
- Forum: Customer/End User Help
- Topic: Module addressing failed problem
- Replies: 10
- Views: 1208
Re: Module addressing failed problem
Yes. Existing batteries were close to 50
44percent.
44percent.
- Sat Jun 22, 2024 10:10 pm
- Forum: Customer/End User Help
- Topic: Module addressing failed problem
- Replies: 10
- Views: 1208
Module addressing failed problem
Hello, I wonder if someone has any suggestions please. I had a new instal in April. With BMS and 3 x Mira HV25 2.45 batteries. I decided to add another battery. Went for Mira HV25 again. Bracket and battery installed all ok. All connected exactly as the foxess YouTube video shows. Dip set to 2 (for ...
- Sun Apr 07, 2024 5:59 pm
- Forum: Customer/End User Help
- Topic: Error code 64
- Replies: 5
- Views: 2886
Re: Error code 64
Thank you very much Dave.
Your knowledge and guidance is greatly appreciated.
I will keep an eye on things.
Your knowledge and guidance is greatly appreciated.
I will keep an eye on things.
- Sun Apr 07, 2024 4:23 pm
- Forum: Customer/End User Help
- Topic: Error code 64
- Replies: 5
- Views: 2886
Re: Error code 64
Hello. I wonder if someone would be able to give some advice please. I have been getting these same error messages. “Error code 64 DC Bus volt is high”. Wondering if ok. Apologies if I do not have the right terminology. I had installed on Weds (scaffold is still up) 16x Longi 430W Panels 6.8kW sys ...