stuck in eps mode
Hi, I turned the isolator off because I though my roofer was going to remove a panel to get access. I realise now that I didn't need to do that anyway but the inverter seems to be stuck in 'EPS Mode' and I have restarted it.
Any ideas? The 2 red fuses seems to be up/on and the grey one is down.

regards
Kevin
Re: stuck in eps mode
FYI resolved it. I was a bit scared of the grey fuse on the right but flicked it up and all good. Not sure why there are 4 fuses and the 2 red ones are labelled as on.
Post Reply