The report query results include the following variables:
generation, feedin, gridconsumption, charge, discharge
I just wanted to confirm that
generation = pv + battery
so that to get a pv figure
pv = generation + charge - discharge

Posts: 2
Joined: Mon May 12, 2025 8:59 am

Posts: 1887
Joined: Thu Oct 13, 2022 7:21 pm
Yes ‘generation’ is all of the work that the inverter has done.
So : Solar generation = (battery charge - battery discharge - grid consumption + loads consumption + feed in)
But note that Fox have recently added the actual PV production to the report with the variable ‘PVEnergyTotal’, this is only available for Hybrid inverters (not solar only which don’t store statistics)
So : Solar generation = (battery charge - battery discharge - grid consumption + loads consumption + feed in)
But note that Fox have recently added the actual PV production to the report with the variable ‘PVEnergyTotal’, this is only available for Hybrid inverters (not solar only which don’t store statistics)

Posts: 2
Joined: Mon May 12, 2025 8:59 am
many thanks
Steven
Steven