Battery drain
HI I have a EP12 Plus 11.52 KW battery and a 6KW inverter installed and running with a Octopus Flux tariff, I am force charging between 02:00 - 05:00 and more a less achieving 100% charge, by 09:00 however most of the charge has gone I am running a 10Kw Heat pump but that's not scheduled to kick in until 08:00
Is it normal for a battery to discharge that quick, the system was only installed in September and i am not sure i I have all setting right I am a very inexperienced newby Solar & heat pumps any assistance advice appreciated

Thanks
Re: Battery drain
I dare say the heat pump is munching the battery pretty hard, I did recommend to Andrew here that he runs the Octopus Cosy tariff viewtopic.php?p=19635#p19635

You get 8hrs of half price electric, and you should use those 3 'sessions' to run heat pump to warm hot water/run heating a little higher.

You can adjust these values to your own needs, also there is an important value in each schedule... 'after cut-off'
Recommend you set this to standby/backup to hold the battery at 100% until the cheap power ends.
Octopus Cosy Schedule.png
Here is the important toggle to hold the battery at 100% in red, note that 'Self-use' will drain the battery.
ExampleWorkMode.png
Re: Battery drain
Hi Thanks very much for your advice I will look to switch tariffs, the last image is very blurred is it possible to resend that image of the battery hold toggle

Thanks again for your help
Re: Battery drain
Click on the 2nd picture again, then hover mouse over picture and you should see a mouse icon with a + symbol when on the picture, clicking a 2nd time should make image full sized.

In case that still does not work, it is just beneath the SoC slider on your schedule.
After Discharge Cut-off.png
Re: Battery drain
Thanks again for your assistance , I have now switched to cosy and made the adjustments to the forced discharge schedule as shown, really sorry to be a pain but could you please also show me what the settings are for the force charging schedule

Thanks again
Re: Battery drain
Those settings are in the first image, click it twice to zoom to 100% scale.

Or open image, then use right-mouse to find the menu (if on windows pc) and left-click on 'Save-as' locate the downloaded file, open and it should be full sized.


Added here, note that you don't need to copy this 100% use it as a template, note that the end time is xx:yy:59s when programmed into the Inverter, so it stops 1 second before the more expensive times.

You may need to set all 3 schedules to 100% SoC
You need to select either 'standby' or 'backup' for what to do after it has reached your specified SoC value
You do this so that it can use the cheaper grid to run the house, and the battery covers 16hrs of the more expensive rate
Full-Sized Charge.png
Post Reply