Hi All,
New user here (hello everyone!) and I've just had a Fox system installed in Scotland with the following:
20x Aiko 490w 9.8kW array
Fox ESS KH8 Inverter
Fox ESS CQ7 Batteries 21kWh
Fox EV Charger (L Series)
The system is producing well (had a decently sunny day today, hooray!), and charging and discharging the battery, but the EV charger is unfortunately using the battery to charge my car when i plug it in.
Now I've seen that there are threads about this, but what what I want to ask is why is it like this? It's clearly quite a sophisticated system, in full communication between the EV charger and the inverter, with solar linkage modes etc, so why isn't there just a setting for "never use battery for EV" ?? Or even "always use grid for EV". Is there a technical reason it can't do this? I'm pretty sure other venders integrated chargers can do this.
I'll need to get this sorted one way or the other and it can't involve micromanaging it with home assistant etc.
20x Aiko Neostar 3S 490W - 9.8kW Array
Fox ESS KH8 Hybrid Inverter - 8kW Power
Fox ESS CQ7 Battery X3 - 21kWh Storage
Fox ESS 7kW L Series EV Charger
Fox ESS KH8 Hybrid Inverter - 8kW Power
Fox ESS CQ7 Battery X3 - 21kWh Storage
Fox ESS 7kW L Series EV Charger
Have a look at where your CT clamps are. My inverter cannot see my car charger, and so when I charge it's just sees any solar surplus. I believe you'll want your CT clamp of your evse after the one for your battery/inverter to make sure they can't see it.
7.36kWp solar array made of 16x Jinko Tiger Neo 460w panels. 8 ESE, 8 WNW facing, Fox EVO 10kWh with 10kW inverter. Installed April 2026. Running ModBus via Elfin EW11A, learning Home Assistant
My EV charger and solar system are both in a detached garage and travel over the same cable making that not possible. If we moved the CT away from the EV charger it would also not see the house load.
I just have no idea why the system can’t do this in software. It knows the house load, it already knows how much the EV charger is drawing. What’s the point in integrating the two if they don’t use the data to let you configure the system?
I just have no idea why the system can’t do this in software. It knows the house load, it already knows how much the EV charger is drawing. What’s the point in integrating the two if they don’t use the data to let you configure the system?
20x Aiko Neostar 3S 490W - 9.8kW Array
Fox ESS KH8 Hybrid Inverter - 8kW Power
Fox ESS CQ7 Battery X3 - 21kWh Storage
Fox ESS 7kW L Series EV Charger
Fox ESS KH8 Hybrid Inverter - 8kW Power
Fox ESS CQ7 Battery X3 - 21kWh Storage
Fox ESS 7kW L Series EV Charger
The CT placement suggestion wouldn't help in your detached garage case anyway, since the EV and house share the same run. You're right that the software already has the inputs: house load and EV draw. The gap seems to be that the charger follows a solar-surplus mode rather than a strict source priority, so battery discharge counts as available supply. Whether Fox exposes a grid-only EV setting probably depends on firmware and whether the EVSE is treated as a controllable load or just follows export. Worth pressing support for the source-priority option rather than rewiring CTs.
There was a Q&A video on Youtube where a representative of FoxESS said that charge from grid only was coming for their EV chargers, although the video is nearly a year old at this point.
I wonder if that is still on the horizon?
- The section on EV chargers starts around 22 mins.
I still think the reversed CT clamp, which effectively cancels out the EV load, could work for me, if I'm understanding the setup correctly? It would go next to the charger and run back to the inverter.
I wonder if that is still on the horizon?
- The section on EV chargers starts around 22 mins.
I still think the reversed CT clamp, which effectively cancels out the EV load, could work for me, if I'm understanding the setup correctly? It would go next to the charger and run back to the inverter.
20x Aiko Neostar 3S 490W - 9.8kW Array
Fox ESS KH8 Hybrid Inverter - 8kW Power
Fox ESS CQ7 Battery X3 - 21kWh Storage
Fox ESS 7kW L Series EV Charger
Fox ESS KH8 Hybrid Inverter - 8kW Power
Fox ESS CQ7 Battery X3 - 21kWh Storage
Fox ESS 7kW L Series EV Charger
The reversed-CT idea still depends on that clamp seeing only the EV circuit, and in a shared garage run it would also see house load, so the cancellation wouldn't be clean. I'd be cautious about relying on a year-old Q&A for a firmware feature; versions change and support may not confirm it. Asking Fox directly whether the EVSE is a controllable load with a source-priority setting seems more reliable than rewiring. If they say grid-only charging is still planned, that answered your question without touching the CTs.
Thanks for the reply.
The idea would have been to put the reversed CT where the Ev charger supply splits from the supply run to the garage, which it must do, and does, to connect up the charger. This would then only see the EV charger load.
I'm not relying on the Q&A really, but i just wanted to gauge whether Fox ESS's communications on stuff like this can be relied upon? It seems not.
The idea would have been to put the reversed CT where the Ev charger supply splits from the supply run to the garage, which it must do, and does, to connect up the charger. This would then only see the EV charger load.
I'm not relying on the Q&A really, but i just wanted to gauge whether Fox ESS's communications on stuff like this can be relied upon? It seems not.
20x Aiko Neostar 3S 490W - 9.8kW Array
Fox ESS KH8 Hybrid Inverter - 8kW Power
Fox ESS CQ7 Battery X3 - 21kWh Storage
Fox ESS 7kW L Series EV Charger
Fox ESS KH8 Hybrid Inverter - 8kW Power
Fox ESS CQ7 Battery X3 - 21kWh Storage
Fox ESS 7kW L Series EV Charger