It is normal that I can not see any parameter on the Slave Inverter and its battery?
I only can see it's prodution on 5 minute snapshot.
Search found 5 matches
- Mon Jun 24, 2024 10:07 am
- Forum: Customer/End User Help
- Topic: H3 Series Master/Slave
- Replies: 3
- Views: 388
- Mon Jun 24, 2024 10:04 am
- Forum: Customer/End User Help
- Topic: H3 Series Master/Slave
- Replies: 3
- Views: 388
Re: H3 Series Master/Slave
Do you have an export limit set ? No export limit set It could also depend on what the work mode is, if you are in self-use you would expect the battery to charge (as long as it needs charge), but if the work mode is set to feed in (or backup) then the batteries would only charge if the AC limit of ...
- Fri Jun 21, 2024 2:41 pm
- Forum: Customer/End User Help
- Topic: H3 Series Master/Slave
- Replies: 3
- Views: 388
H3 Series Master/Slave
Hello guys, I would like to ask for your support with a photovoltaic system that doesn't seem to be working properly. Let's see: - PV system has 2 hybrid inverters (H3-6.0 and 5.0) configured wtih the Master and Slave topology. - At certain point, energy flux is: -- Master Inverter: 6 kW production ...
- Mon Aug 28, 2023 3:56 pm
- Forum: Customer/End User Help
- Topic: Limit Export Energy
- Replies: 2
- Views: 1488
Re: Limit Export Energy
I never thought of that.
It's a solution, I'll add another meter.
Thank you!!!
It's a solution, I'll add another meter.
Thank you!!!
- Mon Aug 21, 2023 3:26 pm
- Forum: Customer/End User Help
- Topic: Limit Export Energy
- Replies: 2
- Views: 1488
Limit Export Energy
Hello, We have an instalation with T25-G3, H3-12.0-E + CUBE 2900 11,6 kWh. Our problem is related with export limitation funcionality. We couldn't put one inverter to control the other one. We have already tried connectiong the meter to T25-G3 and to H3-12.0-E, but it seems that FOX does not have ...