The latest datasheet for the HV25 now has the cycle life as 6000, and not 4000 which it previously had. I guess it's had more testing?
Dave
Search found 3 matches
- Fri Mar 17, 2023 11:24 am
- Forum: Mira HV25
- Topic: Mira HV25 expected life
- Replies: 3
- Views: 3102
- Fri Mar 17, 2023 11:22 am
- Forum: Customer/End User Help
- Topic: Error Code 28 - 10 Minute Average Grid Voltage Fault
- Replies: 29
- Views: 18320
Re: Error Code 28 - 10 Minute Average Grid Voltage Fault
The inverter was reporting RVolt at around 254V for almost an hour at 1.30am two nights ago. I have a H1 5.0 inverter. I contacted my DNO, and they asked me to confirm the voltage with my installer. The graph from foxess shows the voltage fairly consistent at 250V or above. I thought I'd give an ...
- Sun Feb 26, 2023 4:07 pm
- Forum: Customer/End User Help
- Topic: Error Code 28 - 10 Minute Average Grid Voltage Fault
- Replies: 29
- Views: 18320
Re: Error Code 28 - 10 Minute Average Grid Voltage Fault
I have been getting multiple of these every day, and not just during daylight. The inverter was reporting RVolt at around 254V for almost an hour at 1.30am two nights ago. I have a H1 5.0 inverter. I contacted my DNO, and they asked me to confirm the voltage with my installer. The graph from foxess ...