Search found 7 matches

by JanRox
Tue Jul 30, 2024 8:09 pm
Forum: Customer/End User Help
Topic: Night Mode
Replies: 4
Views: 2231

Re: Night Mode

A minor update. Upgrading to the latest firmware does not change the Night mode behaviour.
These are the versions I used:
Master FW: 1.31 to 1.49
Slave FW: 1.01 to 1.02
Manager: 1.20 to 1.24 (I had to downgrade back to 1.20 to get RS-485 to work)
AFCI: 0.23 to 0.25
by JanRox
Tue Jul 30, 2024 8:04 pm
Forum: Customer/End User Help
Topic: RS-485 stopped working after FW upgrade
Replies: 5
Views: 1352

Re: RS-485 stopped working after FW upgrade

Hi I managed to get the RS-485 working by downgrading Manager to version 1.20. This github thread describes how to. https://github.com/assembly12/Foxess-T-series-ESPHome-Home-Assistant/issues/15 Interestingly the FoxEssCloud firmware manager still displays the Manager having version 1.24 after the d...
by JanRox
Tue Jul 09, 2024 8:00 pm
Forum: Customer/End User Help
Topic: RS-485 stopped working after FW upgrade
Replies: 5
Views: 1352

Re: RS-485 stopped working after FW upgrade

The cloud connection is working. Right now I am using the cloud API as a falback solution to get data into my own data presentation system.
'It is working ok but from to time there a timeouts on the data requests. The cloud API is quite slow.

Ok, thanks for your input.

Regards Jan
by JanRox
Wed Jul 03, 2024 7:45 pm
Forum: Customer/End User Help
Topic: RS-485 stopped working after FW upgrade
Replies: 5
Views: 1352

Re: RS-485 stopped working after FW upgrade

Hi Thanks for your swift reply. I will look into your links. What is strange is that I do not get anything at all on the RS-485. And it was working perfect before the upgrade. Maybe the inverter should be restarted or even (factory?) reset? I tried to power off both AC and DC for 10 minutes but no d...
by JanRox
Wed Jul 03, 2024 10:07 am
Forum: Customer/End User Help
Topic: RS-485 stopped working after FW upgrade
Replies: 5
Views: 1352

RS-485 stopped working after FW upgrade

Hi I have a T4-G3 inverter and I have upgraded to latest firmware: Master 1.31 to 1.49 Manager 1.20 to 1.24 Slave 1.01 to 1.02 AFCI 0.23 to 0.25 since I thought it was a good thing to be on latest. But my local RS-485 stopped working after the upgrade. Before upgrade it worked perfect with real-time...
by JanRox
Fri Jun 28, 2024 6:58 pm
Forum: Customer/End User Help
Topic: Night Mode
Replies: 4
Views: 2231

Re: Night Mode

Hi The system has been running now since my last post. It is a strange behaviour. The inverter shuts off in the evening when there are no PV power. In the morning the inverter turns on if I have Night mode enabled, but with Night mode disabled it will not turn on. With Night mode disabled I have to ...
by JanRox
Mon Jun 03, 2024 8:17 pm
Forum: Customer/End User Help
Topic: Night Mode
Replies: 4
Views: 2231

Re: Night Mode

Hi I have the same question. Did you get any information or other insights on Night mode? I have problems with my inverter shutting down during night and not starting up in the morning. If I manually switch the DC off and then on after a minute, then it starts up. Can it be the Night mode that is th...