A minor update. Upgrading to the latest firmware does not change the Night mode behaviour.
These are the versions I used:
Master FW: 1.31 to 1.49
Slave FW: 1.01 to 1.02
Manager: 1.20 to 1.24 (I had to downgrade back to 1.20 to get RS-485 to work)
AFCI: 0.23 to 0.25
Search found 7 matches
- Tue Jul 30, 2024 8:09 pm
- Forum: Customer/End User Help
- Topic: Night Mode
- Replies: 4
- Views: 2582
- Tue Jul 30, 2024 8:04 pm
- Forum: Customer/End User Help
- Topic: RS-485 stopped working after FW upgrade
- Replies: 5
- Views: 1463
Re: RS-485 stopped working after FW upgrade
Hi I managed to get the RS-485 working by downgrading Manager to version 1.20. This github thread describes how to. https://github.com/assembly12/Foxess-T-series-ESPHome-Home-Assistant/issues/15 Interestingly the FoxEssCloud firmware manager still displays the Manager having version 1.24 after the ...
- Tue Jul 09, 2024 8:00 pm
- Forum: Customer/End User Help
- Topic: RS-485 stopped working after FW upgrade
- Replies: 5
- Views: 1463
Re: RS-485 stopped working after FW upgrade
The cloud connection is working. Right now I am using the cloud API as a falback solution to get data into my own data presentation system.
'It is working ok but from to time there a timeouts on the data requests. The cloud API is quite slow.
Ok, thanks for your input.
Regards Jan
'It is working ok but from to time there a timeouts on the data requests. The cloud API is quite slow.
Ok, thanks for your input.
Regards Jan
- Wed Jul 03, 2024 7:45 pm
- Forum: Customer/End User Help
- Topic: RS-485 stopped working after FW upgrade
- Replies: 5
- Views: 1463
Re: RS-485 stopped working after FW upgrade
Hi Thanks for your swift reply. I will look into your links. What is strange is that I do not get anything at all on the RS-485. And it was working perfect before the upgrade. Maybe the inverter should be restarted or even (factory?) reset? I tried to power off both AC and DC for 10 minutes but no ...
- Wed Jul 03, 2024 10:07 am
- Forum: Customer/End User Help
- Topic: RS-485 stopped working after FW upgrade
- Replies: 5
- Views: 1463
RS-485 stopped working after FW upgrade
Hi I have a T4-G3 inverter and I have upgraded to latest firmware: Master 1.31 to 1.49 Manager 1.20 to 1.24 Slave 1.01 to 1.02 AFCI 0.23 to 0.25 since I thought it was a good thing to be on latest. But my local RS-485 stopped working after the upgrade. Before upgrade it worked perfect with real-time ...
- Fri Jun 28, 2024 6:58 pm
- Forum: Customer/End User Help
- Topic: Night Mode
- Replies: 4
- Views: 2582
Re: Night Mode
Hi The system has been running now since my last post. It is a strange behaviour. The inverter shuts off in the evening when there are no PV power. In the morning the inverter turns on if I have Night mode enabled, but with Night mode disabled it will not turn on. With Night mode disabled I have to ...
- Mon Jun 03, 2024 8:17 pm
- Forum: Customer/End User Help
- Topic: Night Mode
- Replies: 4
- Views: 2582
Re: Night Mode
Hi I have the same question. Did you get any information or other insights on Night mode? I have problems with my inverter shutting down during night and not starting up in the morning. If I manually switch the DC off and then on after a minute, then it starts up. Can it be the Night mode that is ...