I have this strange issue with my 2x HV2600 setup that it seems to over time to desync the charge of the two batteries without the controller noticing it.
I don't have clear proof of this as everything seems to be operating normally according to the display and LEDs, but there are two pretty clear ...
Search found 3 matches
- Sun Jan 05, 2025 10:12 pm
- Forum: HV2600
- Topic: Charge status not correctly captured at one of two batteries.
- Replies: 0
- Views: 5421
- Sun May 12, 2024 12:36 am
- Forum: Inverter Hardware
- Topic: Upgrade battery and BMS firmware?
- Replies: 6
- Views: 10400
Re: Upgrade battery and BMS firmware?
Thanks, but that only explains it for the inverter itself.
I received firmware update files for the HV2600 BMS (master & slave) and there is an option in the update inverter update menu for this, but it doesn't find the right folder structure for the BMS firmware.
(I updated the Inverter itself ...
I received firmware update files for the HV2600 BMS (master & slave) and there is an option in the update inverter update menu for this, but it doesn't find the right folder structure for the BMS firmware.
(I updated the Inverter itself ...
- Sun May 05, 2024 1:01 pm
- Forum: Inverter Hardware
- Topic: Upgrade battery and BMS firmware?
- Replies: 6
- Views: 10400
Upgrade battery and BMS firmware?
Hello,
I received the necessary firmware files from the FoxESS support (for my HV2600 battery system), but contrary to the main inverter firmware upgrade it didn't clearly say what folder structure it needs to have on the USB drive to work.
I tried putting them in the same structure as the main ...
I received the necessary firmware files from the FoxESS support (for my HV2600 battery system), but contrary to the main inverter firmware upgrade it didn't clearly say what folder structure it needs to have on the USB drive to work.