Search found 7 matches
- Sat May 06, 2023 9:14 am
- Forum: HV2600
- Topic: Mystery drop in SOC overnight....
- Replies: 20
- Views: 7281
Re: Mystery drop in SOC overnight....
Thanks - the hand-wavy theory makes sense, as it needs to know the full / empty capacity to calibrate the SoC. I've done about 6 full cycles: Charge to 99%, watch battery input drop to 0KW, then discharge to empty when the 0.8KW emergency charging kicks in to top it back up. It still plays silly ...
- Sun Apr 30, 2023 10:14 am
- Forum: HV2600
- Topic: Mystery drop in SOC overnight....
- Replies: 20
- Views: 7281
Re: Mystery drop in SOC overnight....
FWIW, my experience after the upgrade: The SoC is more stable during use; however when the power draw from the battery sits at zero for > 1.5 hours, the SoC will adjust (dropped by ~10%). I also have the same behaviour as before when getting to full charge: SoC rises normally, then jumps by ~20% to ...
- Thu Apr 27, 2023 2:41 pm
- Forum: HV2600
- Topic: Mystery drop in SOC overnight....
- Replies: 20
- Views: 7281
Re: Mystery drop in SOC overnight....
Thanks for the link. The WiFi stick route sounds like a good fall back plan. I got a response from my installer (who received a response from Fox), and they have upgraded the battery FW: I have checked the battery version is 1.0, which has the problem of SOC imbalance. I have upgraded the battery ...
- Tue Apr 25, 2023 1:42 pm
- Forum: HV2600
- Topic: Mystery drop in SOC overnight....
- Replies: 20
- Views: 7281
Re: Mystery drop in SOC overnight....
Master : 1.30, Slave : 1.02, Manager : 1.50
If you find a way to get updated, please let me know
If you find a way to get updated, please let me know
- Tue Apr 25, 2023 8:06 am
- Forum: HV2600
- Topic: Mystery drop in SOC overnight....
- Replies: 20
- Views: 7281
Re: Mystery drop in SOC overnight....
Looks like I was wrong.
Despite top balancing the packs, I still get a 20-25% drop when idle, and can only extract 7.1KWh from 99% to 10% cutoff (on a 10.4KWh pack).
Any suggestions for how to get a warranty claim started, or previous experiences?!
Despite top balancing the packs, I still get a 20-25% drop when idle, and can only extract 7.1KWh from 99% to 10% cutoff (on a 10.4KWh pack).
Any suggestions for how to get a warranty claim started, or previous experiences?!
- Fri Apr 14, 2023 7:28 pm
- Forum: HV2600
- Topic: Mystery drop in SOC overnight....
- Replies: 20
- Views: 7281
Re: Mystery drop in SOC overnight....
I've figured out my issue... I changed the Min SoC to 10% today and let everything discharge to cutoff. I've then checked the voltage on each HV2600 and can see that 2 are slightly higher than the others. Reconfiguring to 2xHV2600 rather than 4 and reconnecting to the inverter shows 30% SoC ...
- Mon Apr 10, 2023 9:50 am
- Forum: HV2600
- Topic: Mystery drop in SOC overnight....
- Replies: 20
- Views: 7281
Re: Mystery drop in SOC overnight....
Did you have any luck getting the SoC drop sorted after an update? I have mine setup to dynamically top up between 1230 and 0430, and during this time set the 'house load' to 0 if no top up is needed. I can repeatably watch the SoC drop by 20 - 25% each night during this idle period. It's a similar ...