Search found 2 matches

by Rainer
Wed Apr 02, 2025 8:22 am
Forum: Customer/End User Help
Topic: H3 12.0e error 64
Replies: 2
Views: 326

Re: H3 12.0e error 64


The fact that there is 0 current and assuming it's daytime might be a issue with the pv wiring.
If that voltage and current is correct then I would first upgrade the firmware to latest and then make sure the pv wiring is correct as per the fox manual. You can't parallel panels. Fox only support ...
by Rainer
Mon Mar 31, 2025 9:03 am
Forum: Customer/End User Help
Topic: H3 12.0e error 64
Replies: 2
Views: 326

H3 12.0e error 64

Hello.

I have installed h3 12.0e inverter. It give me error 64 dc bus volt high but the votlage is only 220 in one string and 300 in other string connected to different mppt. What could be the reason for it?