Search found 7 matches

by Mivera
Thu Apr 04, 2024 1:39 pm
Forum: Hybrid (Solar + Battery)
Topic: FOX inverter H3-5.0-E
Replies: 12
Views: 3226

Re: FOX inverter H3-5.0-E

Your hint to unplugg and replugg the datalogger helps.

Also the loading of the battery in the night ends succussfully without errors.

So it seems, that you have found the incorrect setting, many thanks.
by Mivera
Wed Apr 03, 2024 7:08 pm
Forum: Hybrid (Solar + Battery)
Topic: FOX inverter H3-5.0-E
Replies: 12
Views: 3226

Re: FOX inverter H3-5.0-E

Here is the description of the system Inverter H3-5.0-E Solar modules 4.5 kWp Battery Cube ECS2900 5 kW EPS Commissioning 30.11.23 Since commissioning, the system shows the above described 1. "Starting..." - 2. "Waiting..." - 3. "empty display" behavior. For 3 months I have therefore been switching ...
by Mivera
Wed Apr 03, 2024 4:15 pm
Forum: Hybrid (Solar + Battery)
Topic: FOX inverter H3-5.0-E
Replies: 12
Views: 3226

Re: FOX inverter H3-5.0-E

The screen of the inverter is shows following values this morning, 9:55 Power 62W SoC = 17% 16:20 Power 310 SoC 97% 16:45 Power 500W SoC = 100% It seems that the inverter is running, but the battery is not used. It is a rainy day and I do not expect SoC = 100%. The app still shows no data since 5:18 ...
by Mivera
Wed Apr 03, 2024 9:28 am
Forum: Hybrid (Solar + Battery)
Topic: FOX inverter H3-5.0-E
Replies: 12
Views: 3226

Re: FOX inverter H3-5.0-E

I've enabled the charging time from 3 to 6 o'clock this morning with SoC on grid = 15% and max grid = 25%. Since 5:18 this morning the app shows status Offline. So I have no Information about the current behaviour in the app. It seems that the charging from grid caused the Offline. Can you please ...
by Mivera
Tue Apr 02, 2024 1:35 pm
Forum: Hybrid (Solar + Battery)
Topic: FOX inverter H3-5.0-E
Replies: 12
Views: 3226

Re: FOX inverter H3-5.0-E

Thanks for your answer.

Max SoC = 100%

In the user manual guide I havent found a good description or a preferred value for this parameter.

Is Max Soc only the charging limit of the battery for charging from the grid or has it also an influence of charging the battery from solar?
by Mivera
Mon Apr 01, 2024 7:09 pm
Forum: Hybrid (Solar + Battery)
Topic: FOX inverter H3-5.0-E
Replies: 12
Views: 3226

Re: FOX inverter H3-5.0-E

The inverter is connected with the grid.

But I don't want to use expensive power from the grid to charge the battery.
The battery should be charged only by solar.

The inverter work model is "Self-Use". and charge from grid for the battery is not enabled.
by Mivera
Mon Apr 01, 2024 2:57 pm
Forum: Hybrid (Solar + Battery)
Topic: FOX inverter H3-5.0-E
Replies: 12
Views: 3226

FOX inverter H3-5.0-E

Since December '23, I have owned a photovoltaic system from FOX. The inverter model H3-5.0-E with battery storage shows the following behavior: After dark and discharging the battery to the defined SoC Grid value, the inverter attempts to restart every 15 seconds . This is indicated on the inverter ...