Re: Use battery as a buffer even during charging period
The battery will always be used to fill the gap of solar unless you have charge period set and grid charge switch set off I have charge period set and grid charge on. I feel that allowing battery to, as You nicely phrased, "fill the gap" as long as SoC stays above Max SoC even during charge period ...
- Mon Mar 11, 2024 2:31 pm
- Forum: Hybrid (Solar + Battery)
- Topic: Use battery as a buffer even during charging period
- Replies: 2
- Views: 1604
Use battery as a buffer even during charging period
Hello, so far I noticed behaviour during charging window: - if Force charge / Charge from grid is enabled and there is not enough sun to reach Max charging current , inverter will draw power from the grid to charge up to Max SoC - if Max SoC is reached and still there is some sun, it always charges ...
- Mon Mar 11, 2024 12:13 pm
- Forum: Hybrid (Solar + Battery)
- Topic: H3 Hybrid Inverter MODBUS Protocol
- Replies: 2
- Views: 1643
Re: H3 Hybrid Inverter MODBUS Protocol
If I understand things correctly: Load is power consumed by the house, should always be positive and is not measured but calculated as sum of those two: - Meter is measured at grid - home installation joint; negative -> export to the grid - Inverter Power is power of inverter's "On Grid" inlet ...
- Mon Nov 13, 2023 2:38 pm
- Forum: Customer/End User Help
- Topic: Strange battery discharge
- Replies: 7
- Views: 1893
Re: Strange battery discharge
I noticed something very similar and am happy to find this thread when searching for the solution. Some time ago I called my installer qith question: "why, when battery reaches Min SoC [15%], does inverter display -130W instead of -15W [expected standby power]?" He justified that this display in ...