Search found 4 matches

by Bobinho
Sat Mar 23, 2024 4:54 pm
Forum: Hybrid (Solar + Battery)
Topic: Use battery as a buffer even during charging period
Replies: 2
Views: 1604

Re: Use battery as a buffer even during charging period

The battery will always be used to fill the gap of solar unless you have charge period set and grid charge switch set off I have charge period set and grid charge on. I feel that allowing battery to, as You nicely phrased, "fill the gap" as long as SoC stays above Max SoC even during charge period ...
by Bobinho
Mon Mar 11, 2024 2:31 pm
Forum: Hybrid (Solar + Battery)
Topic: Use battery as a buffer even during charging period
Replies: 2
Views: 1604

Use battery as a buffer even during charging period

Hello, so far I noticed behaviour during charging window: - if Force charge / Charge from grid is enabled and there is not enough sun to reach Max charging current , inverter will draw power from the grid to charge up to Max SoC - if Max SoC is reached and still there is some sun, it always charges ...
by Bobinho
Mon Mar 11, 2024 12:13 pm
Forum: Hybrid (Solar + Battery)
Topic: H3 Hybrid Inverter MODBUS Protocol
Replies: 2
Views: 1643

Re: H3 Hybrid Inverter MODBUS Protocol

If I understand things correctly: Load is power consumed by the house, should always be positive and is not measured but calculated as sum of those two: - Meter is measured at grid - home installation joint; negative -> export to the grid - Inverter Power is power of inverter's "On Grid" inlet ...
by Bobinho
Mon Nov 13, 2023 2:38 pm
Forum: Customer/End User Help
Topic: Strange battery discharge
Replies: 7
Views: 1893

Re: Strange battery discharge

I noticed something very similar and am happy to find this thread when searching for the solution. Some time ago I called my installer qith question: "why, when battery reaches Min SoC [15%], does inverter display -130W instead of -15W [expected standby power]?" He justified that this display in ...