Search found 4 matches

by Bobinho
Sat Mar 23, 2024 4:54 pm
Forum: Hybrid (Solar + Battery)
Topic: Use battery as a buffer even during charging period
Replies: 2
Views: 2923

Re: Use battery as a buffer even during charging period

The battery will always be used to fill the gap of solar unless you have charge period set and grid charge switch set off
I have charge period set and grid charge on.

I feel that allowing battery to, as You nicely phrased, "fill the gap" as long as SoC stays above Max SoC even during charge ...
by Bobinho
Mon Mar 11, 2024 2:31 pm
Forum: Hybrid (Solar + Battery)
Topic: Use battery as a buffer even during charging period
Replies: 2
Views: 2923

Use battery as a buffer even during charging period

Hello,

so far I noticed behaviour during charging window:
- if Force charge / Charge from grid is enabled and there is not enough sun to reach Max charging current , inverter will draw power from the grid to charge up to Max SoC
- if Max SoC is reached and still there is some sun, it always ...
by Bobinho
Mon Mar 11, 2024 12:13 pm
Forum: Hybrid (Solar + Battery)
Topic: H3 Hybrid Inverter MODBUS Protocol
Replies: 2
Views: 3242

Re: H3 Hybrid Inverter MODBUS Protocol

If I understand things correctly:
Load is power consumed by the house, should always be positive and is not measured but calculated as sum of those two:
- Meter is measured at grid - home installation joint; negative -> export to the grid
- Inverter Power is power of inverter's "On Grid" inlet ...
by Bobinho
Mon Nov 13, 2023 2:38 pm
Forum: Customer/End User Help
Topic: Strange battery discharge
Replies: 7
Views: 5412

Re: Strange battery discharge

I noticed something very similar and am happy to find this thread when searching for the solution.

Some time ago I called my installer qith question:
"why, when battery reaches Min SoC [15%], does inverter display -130W instead of -15W [expected standby power]?"