Hi
My solar system was upset when I had a heat pump installed and they fiddled about with the electrics. It says Code-169.
Is this something I can reset myself?
Thanks.
Inverter fault 169
-
- Posts: 1411
- Joined: Thu Oct 13, 2022 7:21 pm
That's a strange error (sample fault) - I think the first step would be to do a full restart on your inverter.
Basically you have to open the PV isolator, open the AC isolator, power off the batteries - wait 30 seconds and then reverse the process. - - this video guide will help to do that. viewtopic.php?t=5
If that doesn't work, I would suggest emailing Fox service service.uk@fox-ess.com with your inverter serial number and ask them to review it (they can do that remotely)
Basically you have to open the PV isolator, open the AC isolator, power off the batteries - wait 30 seconds and then reverse the process. - - this video guide will help to do that. viewtopic.php?t=5
If that doesn't work, I would suggest emailing Fox service service.uk@fox-ess.com with your inverter serial number and ask them to review it (they can do that remotely)