Search found 3 matches

by DaveP
Tue Dec 19, 2023 1:52 pm
Forum: LV52/LV54/LV5200 (Low Voltage)
Topic: LV5200 and Solis RHI-5K-48ES-5G - HighVolt.BMS(33293) Alarm
Replies: 15
Views: 7977

Re: LV5200 and Solis RHI-5K-48ES-5G - HighVolt.BMS(33293) Alarm

Hi, after my original post and no responses for a few weeks I gave up checking this forum and haven't received any notifications of the numerous responses made, so apologies for not responding sooner. Anyway, after my original post I contacted Fox and received a visit to my home where the battery ...
by DaveP
Sat Jul 22, 2023 11:58 am
Forum: LV52/LV54/LV5200 (Low Voltage)
Topic: LV5200 purple and white label compatibility
Replies: 2
Views: 2255

Re: LV5200 purple and white label compatibility

Have you tried contacting Fox directly? I had a fairly quick response from them to my query I also asked in a separate thread on here but received no replies as it seems a bit light on activity. I’ve just added 2 additional lv5200 batteries to my 2 existing ones but they were all purple labels. Fox d ...
by DaveP
Sun Jul 02, 2023 3:13 pm
Forum: LV52/LV54/LV5200 (Low Voltage)
Topic: LV5200 and Solis RHI-5K-48ES-5G - HighVolt.BMS(33293) Alarm
Replies: 15
Views: 7977

LV5200 and Solis RHI-5K-48ES-5G - HighVolt.BMS(33293) Alarm