Search found 7 matches
- Mon Jan 23, 2023 10:38 am
- Forum: Customer/End User Help
- Topic: Battery Charging issue after adding 2 additional batteries
- Replies: 11
- Views: 3091
Re: Battery Charging issue after adding 2 additional batteries
Thanks all for the advice here! Happy to report that force charging them in pairs worked very well. 1. Disconnected the old v1 bats first and force charge the v2's. 2. Disconnected the v2 bats from the BMS and swapped them with the v1's then force charged the v1's. 3. Once 100% SOC, install the bats ...
- Wed Jan 18, 2023 9:41 am
- Forum: Customer/End User Help
- Topic: Battery Charging issue after adding 2 additional batteries
- Replies: 11
- Views: 3091
Re: Battery Charging issue after adding 2 additional batteries
@SolarJunkie Yep, I got the V2 BMS installed and setup. Your mention of the firmware is a good shout for me to ask my installer to update everything to the latest as I only have an end user account. @Dave Foster When I first installed the V2 BMS I did get those 2 errors and found this post which I ...
- Tue Jan 17, 2023 12:05 pm
- Forum: Customer/End User Help
- Topic: Battery Charging issue after adding 2 additional batteries
- Replies: 11
- Views: 3091
Battery Charging issue after adding 2 additional batteries
I've recentlly added 2 additional HV2600's on top of my existing 2 HV2600 but noticed that it only seems to continue charging as if theres only 2 total, not the 4 currently connected. Setup (in physical order) - BMS v2 - HV2600 v2 - HV2600 v2 - HV2600 v1 - HV2600 v1 Other info - DIP switch = 2 ...
- Mon Jan 16, 2023 3:07 pm
- Forum: HV2600
- Topic: BMS V2 with mixed v1/v2 batteries - Solution to persistent BMS alarms.
- Replies: 15
- Views: 12146
Re: BMS V2 with mixed v1/v2 batteries - Solution to persistent BMS alarms.
I recentlly got my v2 BMS and experienced the exact same issues as yourself. I followed up with my contact in FoxESS who did my RMA and they are not only working on the issue but also preparing modified patch cables (such as the one you've posted) to send out. They kindly send me one the same day I ...
- Wed Dec 14, 2022 5:30 pm
- Forum: Customer/End User Help
- Topic: Solar Reporting
- Replies: 17
- Views: 15009
Re: Solar Reporting
On the cloud site there is a "Total Yield" under Sites > MySites which will tell you total gen since your site has been communicating with FoxESS Cloud service. Doubt it'll be 100% accurate with data missing due to the cloud service being out or your own internet going offline. As for seeing ...
- Tue Dec 13, 2022 4:37 pm
- Forum: Customer/End User Help
- Topic: Agent account on my site
- Replies: 1
- Views: 893
Agent account on my site
Hi everyone, Does anyone know if it's possible to have multiple "agent" accounts assisgned to a single site? I'd like to be able to personally manage some areas (e.g. firmware updates) which are not accessable on an end user account. I did email my installer but they have advised they I'll lose ...
- Mon Nov 28, 2022 9:44 pm
- Forum: HV2600
- Topic: Force discharge to grid
- Replies: 12
- Views: 6902
Force discharge to grid
Does anyone know if it's possible to force discharge these back to the grid? Seems force charge from grid is an option within the cloud interface but aside from that I can't see anything in the manual but i'm far from an expert!