Search found 3 matches
- Fri Nov 25, 2022 10:09 pm
- Forum: LV52/LV54/LV5200 (Low Voltage)
- Topic: LV5200 Battery Charge rate ?
- Replies: 14
- Views: 7737
Re: LV5200 Battery Charge rate ?
Issue is where battery is installed - Loft space and temperature in that space at this time of year : BMS will not allow a charge below 0 deg. C, between 0 and 5 deg. C it's limited to 10A, from 5 to 10 deg. C it's limited to 15A, 10 to 15 deg. C is 25A, rising to 50A by 20 deg. C and above. so amps ...
- Fri Nov 25, 2022 10:36 am
- Forum: LV52/LV54/LV5200 (Low Voltage)
- Topic: LV5200 Battery Charge rate ?
- Replies: 14
- Views: 7737
Re: LV5200 Battery Charge rate ?
Additional info : we are sending most of the excess to the grid - battery WILL ONY CHARGE at 0.6kwh - this has to be wrong ? yield 2.045 kwh house consumption 0.417 kwh battery 35% charged and charging at 0.659 kwh - charge limit is 12 a currently - I have seen this up to 50a at random times ...
- Thu Nov 24, 2022 2:35 pm
- Forum: LV52/LV54/LV5200 (Low Voltage)
- Topic: LV5200 Battery Charge rate ?
- Replies: 14
- Views: 7737
LV5200 Battery Charge rate ?
Hi we have a new PV installation - Solis Inverter RHI 6K 48ES 5G with a Fox ESS LV5200 Battery. we have seen some issues, but most resolved, however Solis support are stating that the Battery BMS is restricting the charge rate to be 12 A? They say they cannot change this and by my calculation this ...