Search found 2 matches

by bfayers
Tue Nov 05, 2024 10:59 am
Forum: Home Assistant
Topic: Trying to understand some of the charging related sensors? (H1-G2, EP11)
Replies: 2
Views: 201

Re: Trying to understand some of the charging related sensors? (H1-G2, EP11)

The BMS Charge Rate sensor is the BMS telling the inverter what the maximum allowable charge rate is, it calculates this based on SoC and temperature - and it will reduce this figure as it approaches 90% or the temp drops below 20C. This is the absolute maximum it can charge at, but obviously you ...
by bfayers
Mon Nov 04, 2024 8:09 pm
Forum: Home Assistant
Topic: Trying to understand some of the charging related sensors? (H1-G2, EP11)
Replies: 2
Views: 201

Trying to understand some of the charging related sensors? (H1-G2, EP11)

I've recently had an H-6.0-E-G2 installed and two EP11 batteries. I'm trying to understand what some of the charging related sensors in HASS are actually referring to. I'm on intelligent octopus go, so I'm charging between 23:30 and 05:30. Last night my batteries were charging at ~3kW (I figure ...