Search found 5 matches

by Omka
Tue Jan 07, 2025 9:37 pm
Forum: Customer/End User Help
Topic: WiFi Dongle, Fox H3 Pro 20.
Replies: 2
Views: 737

Re: WiFi Dongle, Fox H3 Pro 20.

I reviewed the other systems I’ve installed, and all the PRO versions have Q1 dongles. Could someone advise where I can buy them or provide the model number of the dongles to order?
by Omka
Tue Jan 07, 2025 9:05 pm
Forum: Customer/End User Help
Topic: WiFi Dongle, Fox H3 Pro 20.
Replies: 2
Views: 737

WiFi Dongle, Fox H3 Pro 20.

WiFi Dongle, Fox H3 Pro 20.
Hello, I encountered an issue. During the move, the dongle was lost. I started looking to order a new one, but there are many types available: v2, v3, v4, v5, q1, L1, etc. I ordered the one designed for a local network (via cable), removed the old dongle, and added the ...
by Omka
Wed Dec 04, 2024 10:53 am
Forum: Customer/End User Help
Topic: Fox h3 25 , maximum volt for one mppt ?
Replies: 3
Views: 601

Re: Fox h3 25 , maximum volt for one mppt ?


On the H3 Pro the maximum voltage for each MPPT is 1,000 volts i.e. you can have 3 * MPPT's each with a maximum of 1,000 volts.

As voltage isn't measured in series, the maximum voltage will never be any higher than 1000V on any input.

But please note that whilst the maximum is 1,000V, the ...
by Omka
Wed Dec 04, 2024 9:26 am
Forum: Customer/End User Help
Topic: Fox h3 25 , maximum volt for one mppt ?
Replies: 3
Views: 601

Fox h3 25 , maximum volt for one mppt ?

Good day, I have a question: I have a fox h3 25 kW. There are 3 mppt channels, each channel has two inputs. The specifications say a maximum of 1000 volts. 1000 volts for one mppt? Or 1000 for one input, and then it turns out that for one mppt you can have 1000+1000? What is correct?
by Omka
Mon Nov 04, 2024 6:16 pm
Forum: Customer/End User Help
Topic: dual smart meter problem
Replies: 0
Views: 1319

dual smart meter problem

There is a problem, we have
Fox h3 12e, ev charger, dual smart meter.
First channel rs485: 24,25:
24 (a) pin of the meter for 4 ev charger.
25 (b) pin of the meter for 2 ev charger.
Second channel rs485: 19,21:
19 (a2) pin of the meter for 4 inverters.
21 (b2) pin of the meter for 3 inverters.
In ...