Search found 16 matches

by v1lad
Tue May 07, 2024 10:01 am
Forum: Hybrid (Solar + Battery)
Topic: Draw from grid
Replies: 11
Views: 1383

Re: Draw from grid

It's definitely not a good thing that invertors require a small amount of energy from the grid. Here in Germany, we buy energy at 30 cents and sell it at a fixed price of 8.6 cents.
by v1lad
Tue May 07, 2024 9:53 am
Forum: Hybrid (Solar + Battery)
Topic: Modbus Daily and Total reg data screwed up from 6th May.
Replies: 2
Views: 429

Re: Modbus Daily and Total reg data screwed up from 6th May.

Seems it is issue between HA<----->ESPHome communication. Raw data in ESPHome is correct for Total too. Example: [09:22:03][D][modbus_controller.sensor:025]: Sensor new state: 5137.00 [09:22:03][D][sensor:093]: 'Battery Charge total': Sending state 513.70001 kWh with 1 decimals of accuracy [09:22:03...
by v1lad
Tue May 07, 2024 8:01 am
Forum: Hybrid (Solar + Battery)
Topic: Modbus Daily and Total reg data screwed up from 6th May.
Replies: 2
Views: 429

Modbus Daily and Total reg data screwed up from 6th May.

If anyone's had the same problem. Since yesterday the daily and total values are not displayed correctly in HA. Momentary values are correct. As example : h3web Battery Discharge daily 5,435.5 kWh h3web Feed-in daily 6,534.3 kWh Raw data from ESPHome are correct. Example: [09:22:03][D][modbus_contro...
by v1lad
Thu Mar 21, 2024 6:35 pm
Forum: Inverter Hardware
Topic: Potential ESP32 comms interface
Replies: 7
Views: 2367

Re: Potential ESP32 comms interface

Hi !
I have very simple integration based on ESP8266 :
https://github.com/mypi-home/HA-ESPHome ... ter-Modbus
I have to change just script from H1 to H3. It is working fine. The device is placed in a DIN rail case. After debugging I will install it to the Electrical Control Panel.
by v1lad
Thu Mar 21, 2024 3:11 pm
Forum: Hybrid (Solar + Battery)
Topic: H3 Hybrid Inverter MODBUS Protocol
Replies: 2
Views: 499

Re: H3 Hybrid Inverter MODBUS Protocol

Seems you are right and I have mistake in decoding of Load figures.
I will double check again.
I have very simple integration based on ESP8266. See here
https://github.com/mypi-home/HA-ESPHome ... ter-Modbus
by v1lad
Fri Mar 08, 2024 5:01 pm
Forum: Hybrid (Solar + Battery)
Topic: H3 Hybrid Inverter MODBUS Protocol
Replies: 2
Views: 499

H3 Hybrid Inverter MODBUS Protocol

Hi All ! can anyone explain the physical meaning of the raw data ? Meter powerR 31026 Meter powerS 31027 Meter powerT 31028 Load powerR 31029 Load powerS 31030 Load powerT 31031 I think I understand how Meter shows this. Positive figures are Feed-In, negative figures are grid consumption, but I can ...
by v1lad
Fri Feb 09, 2024 10:35 am
Forum: Hybrid (Solar + Battery)
Topic: How to get access to modbus data (H3)
Replies: 9
Views: 2189

Re: How to get access to modbus data (H3)

Hi All ! Modbus error function code: 0x83 exception: 2 It seems that I have a communication via UART, but the response is wrong. What can be the reason for this? I have made the issue here and attached log and config. https://github.com/mypi-home/HA-ESPHome-FOXESS-Inverter-Modbus/issues/1 P.S. Issue...
by v1lad
Thu Jan 18, 2024 7:58 am
Forum: Hybrid (Solar + Battery)
Topic: PVPower PVCurrent PVVolt - correlation.
Replies: 3
Views: 1350

Re: PVPower PVCurrent PVVolt - correlation.

Hi Dave! Thank you very much for your answer. The inverter is running without any errors in the log. The battery is attached, and the state of charge is at 13-14% (the settings specify a minimum of 15% on the grid and 10% without the grid). There are no limits for export, and during this time, the h...
by v1lad
Wed Jan 17, 2024 7:53 am
Forum: Hybrid (Solar + Battery)
Topic: PVPower PVCurrent PVVolt - correlation.
Replies: 3
Views: 1350

PVPower PVCurrent PVVolt - correlation.

Hi All ! As everyone has known since school : PVPower = PVVolt x PVCurrent Now let's take a look at the chart. I have 20 panels, but the strings connections were not made identically. Why at high enough voltage from solar panels, the current is still 0, and therefore the power is also 0 ? Is the thr...
by v1lad
Mon Dec 18, 2023 6:42 pm
Forum: Hybrid (Solar + Battery)
Topic: How to get access to modbus data (H3)
Replies: 9
Views: 2189

Re: How to get access to modbus data (H3)

Hi All ! I am going to connect adapter with twisted pair cable. Before I started to disassemble H3 connector, would be good to understand how to fix the wire in the socket ? How should the end of the wire be prepared ? Thanks in advance for the help. P.S. If anyone is interested, I'm going to connec...
by v1lad
Mon Dec 18, 2023 6:18 pm
Forum: Hybrid (Solar + Battery)
Topic: Feed-in power shows with battery charged only 15-20%
Replies: 3
Views: 888

Re: Feed-in power shows with battery charged only 15-20%

Thank you very much for the explanation. I also took the measurements directly from the inverter. See the attached picture.
Of course the amount is very small, but it is there.
by v1lad
Mon Dec 18, 2023 2:57 pm
Forum: Hybrid (Solar + Battery)
Topic: Feed-in power shows with battery charged only 15-20%
Replies: 3
Views: 888

Feed-in power shows with battery charged only 15-20%

HI all !
I find strange behavior of my installation. The installation does a short power export several times a day, with the battery only 15-20% charged. See attached pic. Can anyone explain this behavior ? Thanks in advance.
by v1lad
Sun Dec 17, 2023 11:39 am
Forum: Hybrid (Solar + Battery)
Topic: New User: Step One - overnight battery charging
Replies: 8
Views: 1929

Re: New User: Step One - overnight battery charging

Dave Foster wrote: Sun Dec 17, 2023 11:22 am It is written by a forum member so at least he is well known, I guess you take your chances but not forgetting your data is stored in China on Chinese servers.
yes this is a very interesting question, how does this comply with GDPR.
by v1lad
Sun Dec 17, 2023 10:13 am
Forum: Hybrid (Solar + Battery)
Topic: New User: Step One - overnight battery charging
Replies: 8
Views: 1929

Re: New User: Step One - overnight battery charging

Dave Foster wrote: Sun Dec 17, 2023 9:07 am There is a 3rd party app called Energy Stats written by Al Priest.
But in this case, you are giving access and have to fully trust this app that it doesn't have a back door to your data.
by v1lad
Mon Dec 11, 2023 11:12 am
Forum: Customer/End User Help
Topic: Ongoing issues following maintenance over the weekend?
Replies: 14
Views: 2151

Re: Ongoing issues following maintenance over the weekend?

Hi ! Finally cloud APP shows only 0 for me, but devices are working correctly.
by v1lad
Thu Dec 07, 2023 9:37 pm
Forum: Hybrid (Solar + Battery)
Topic: Inverter Self-Power consumption / efficiency
Replies: 12
Views: 3130

Re: Inverter Self-Power consumption / efficiency

HI All ! I faced the same situation after this morning's update. My inverter is now consistently drawing 150W from the grid at night with the battery at minimum ( 10% ). Update was from 1.56 to 1.71. I have found solution: Factory Reset, after you need just set up safety standard / country code and ...