Search found 10 matches

by UK_KH_User123
Thu Mar 28, 2024 3:49 pm
Forum: Customer/End User Help
Topic: KH should I update?
Replies: 6
Views: 1067

Re: KH should I update?

Yes, it began working again quickly. Each side of the consumer unit (the whole unit is on the EPS output) has an 80A RCD. Probably just a fluke.
by UK_KH_User123
Thu Mar 28, 2024 11:21 am
Forum: Customer/End User Help
Topic: KH should I update?
Replies: 6
Views: 1067

Re: KH should I update?

Spoke too soon! Next round did the 'master': Master : 1.29. Slave : 1.01. Manager : 1.21 That part of the upgrade did throw the device into EPS mode as if the AC power failed which in this case tripped one of the RCDs in the consumer unit meaning power was lost to many circuits in the house. The ...
by UK_KH_User123
Thu Mar 28, 2024 11:02 am
Forum: Customer/End User Help
Topic: KH should I update?
Replies: 6
Views: 1067

Re: KH should I update?

Ok... I was impatient and feeling lucky, so I asked for an upgrade and received it. Only the manager was updated:

Master : 1.27 Slave : 1.01. Manager : 1.21

I'll report back if I find any problems.
by UK_KH_User123
Wed Mar 27, 2024 7:22 pm
Forum: Customer/End User Help
Topic: KH should I update?
Replies: 6
Views: 1067

KH should I update?

Hello: I'm hoping maybe William will answer but all are welcome. I have a KH10.5 and I'm on firmware from a month or so ago (Master : 1.27 Slave : 1.01 Manager : 1.19). I know firmware was updated since then. I'm not having any problems but do like to keep current unless there are drawbacks ...
by UK_KH_User123
Fri Dec 15, 2023 8:47 pm
Forum: Pre-sales Questions
Topic: KH-Series 10.5 hybrid inverter software/firmware
Replies: 15
Views: 5199

Re: KH-Series 10.5 hybrid inverter software/firmware

This is my inverter ... confirm latest firmware did not give me that function. It did add 'peak shaving' and it did subtract the ability for the foxesscloud to work properly with the inverter. Local control (panel and modbus) are fine. Well, actually I've had some inverter operating system freezes ...
by UK_KH_User123
Fri Dec 08, 2023 9:25 am
Forum: Customer/End User Help
Topic: Setting "Low Power" - EPS - UPS
Replies: 4
Views: 1567

Re: Setting "Low Power" - EPS - UPS

follow-up question:

regarding firmware parts - am I correct that Manager = inverter's software, Master = main battery (BMS) software, Slave = all the other batteries' software?
by UK_KH_User123
Thu Dec 07, 2023 2:16 pm
Forum: Customer/End User Help
Topic: Issue logging into www.foxesscloud.com
Replies: 6
Views: 2357

Re: Issue logging into www.foxesscloud.com

It should work, I have both working and the same credentials are used. My web login is using the username, not the email address ... could that be the problem? I can't give an accurate answer of what you can and can't do, additionally, on the web site, but that's how I prefer to interact with the ...
by UK_KH_User123
Thu Dec 07, 2023 2:01 pm
Forum: Customer/End User Help
Topic: Setting "Low Power" - EPS - UPS
Replies: 4
Views: 1567

Re: Setting "Low Power" - EPS - UPS

Thanks for the reply, Dave! It uses about 200 watts when the house load is about 500 watts. This is when there is no solar generation and the grid is connected, but not being used for supply or charging (so I'm running from battery). I'm looking at the difference between the power drawn out of the ...
by UK_KH_User123
Sun Dec 03, 2023 9:19 pm
Forum: Customer/End User Help
Topic: Setting "Low Power" - EPS - UPS
Replies: 4
Views: 1567

Setting "Low Power" - EPS - UPS

Hello: I have a KH10.5 inverter wtih solar and batteries. I run my entire house load from the EPS output (though the system is grid-tied as one would expect). I noticed a setting, under the Settings > Feature > Low Power, where I can choose to turn on "Low Power". It is not on now, and I'd like to ...
by UK_KH_User123
Sat Oct 14, 2023 2:05 pm
Forum: Customer/End User Help
Topic: Maximising feed-in
Replies: 7
Views: 3674

Re: Maximising feed-in

Hello... I also might want to do some battery feed-in from my KH 10.5 inverter. I just wanted to post that the RS485 connection does provide some more options (and much quicker updates) than the web site interface, but it does not provide any controls that are not also available from the front panel ...