Re: Grid Pressure/Push back Setting added to the K and H1-gen2
Nice .. thanks for the pic!
- Wed Mar 05, 2025 8:11 pm
- Forum: Customer/End User Help
- Topic: Fitting meter instead of CT
- Replies: 4
- Views: 3793
Re: Fitting meter instead of CT
I can't find the inverter meter specs anywhere, but is the inverter expecting the defaults:
modbus address 1 (that one I know it is)
baud rate 9600
parity none
The specs of the Eastsron SDM230 Modbus don't seem too impressive in regard to accuracy:
Accuracy
• Voltage 0·5% of range maximum ...
modbus address 1 (that one I know it is)
baud rate 9600
parity none
The specs of the Eastsron SDM230 Modbus don't seem too impressive in regard to accuracy:
Accuracy
• Voltage 0·5% of range maximum ...
- Wed Mar 05, 2025 6:43 pm
- Forum: Customer/End User Help
- Topic: Fitting meter instead of CT
- Replies: 4
- Views: 3793
Re: Fitting meter instead of CT
Great Dave, I'll look for one of those. Thanks again!
- Wed Mar 05, 2025 6:17 pm
- Forum: Customer/End User Help
- Topic: Fitting meter instead of CT
- Replies: 4
- Views: 3793
Fitting meter instead of CT
Hello!
I'm going to have a little re-working done to my system and I'm interested in having my installer (or some electrician) change from using CT1 to Meter 1 for the inverter's main sensing of the grid current flow.
Can I just source any 63A (or higher) Modbus meter, set it to Modbus ID1 ...
I'm going to have a little re-working done to my system and I'm interested in having my installer (or some electrician) change from using CT1 to Meter 1 for the inverter's main sensing of the grid current flow.
Can I just source any 63A (or higher) Modbus meter, set it to Modbus ID1 ...
- Thu Feb 27, 2025 5:29 pm
- Forum: Customer/End User Help
- Topic: Off grid setup with Generator backup supply
- Replies: 22
- Views: 29576
Re: Off grid setup with Generator backup supply
Yes, thanks ... if I try to write values 0,8000 starting at 46616 it works.
Is the crowd-sourced current state of registers published somewhere?
Is the crowd-sourced current state of registers published somewhere?
- Thu Feb 27, 2025 11:13 am
- Forum: Customer/End User Help
- Topic: Off grid setup with Generator backup supply
- Replies: 22
- Views: 29576
Re: Off grid setup with Generator backup supply
You're amazing Dave! Thanks.
I'm on KH10.5 Master 1.4 / Slave 1.01 / ARM 1.37 (that's Manager I guess).
Reading input registers, also same for holding registers:
values:
"46616": 0
"46617": 9000
Reading input register 41012
values:
"41012": 9000
This matches my current Settings > On ...
I'm on KH10.5 Master 1.4 / Slave 1.01 / ARM 1.37 (that's Manager I guess).
Reading input registers, also same for holding registers:
values:
"46616": 0
"46617": 9000
Reading input register 41012
values:
"41012": 9000
This matches my current Settings > On ...
- Wed Feb 26, 2025 7:46 pm
- Forum: Customer/End User Help
- Topic: Off grid setup with Generator backup supply
- Replies: 22
- Views: 29576
Re: Off grid setup with Generator backup supply
Exactly Dave, on all counts!
Thanks for going through it all again, I know it is a lot. I was hoping that using CT2 was some sort of magic potion that would solve some issues. I think you are confirming for my set up there is no benefit to doing that.
To be more clear, my concern about backflow is ...
Thanks for going through it all again, I know it is a lot. I was hoping that using CT2 was some sort of magic potion that would solve some issues. I think you are confirming for my set up there is no benefit to doing that.
To be more clear, my concern about backflow is ...
- Wed Feb 26, 2025 4:52 pm
- Forum: Customer/End User Help
- Topic: Off grid setup with Generator backup supply
- Replies: 22
- Views: 29576
Re: Off grid setup with Generator backup supply
Question - in this arrangement, using CT2 (or two meters), does the inverter 'know' it is off-grid (grid is down) when it sees no current on the grid CT/meter but does see current on the 'additional generator' CT/meter? Does this set up prevent all backflow from the inverter to the generator? My ...
- Sun Feb 23, 2025 4:36 pm
- Forum: Customer/End User Help
- Topic: Off grid setup with Generator backup supply
- Replies: 22
- Views: 29576
Re: Off grid setup with Generator backup supply
:)
Thanks Dave!
It’s a complex answer and takes some planning, firstly it is illegal to connect any other generator to the incoming supply connections and so in the event of grid failure you must fully isolate the incoming supply so that anything you do within the home is isolated from the ...
Thanks Dave!
It’s a complex answer and takes some planning, firstly it is illegal to connect any other generator to the incoming supply connections and so in the event of grid failure you must fully isolate the incoming supply so that anything you do within the home is isolated from the ...
- Sun Feb 23, 2025 12:05 pm
- Forum: Customer/End User Help
- Topic: Off grid setup with Generator backup supply
- Replies: 22
- Views: 29576
Re: Off grid setup with Generator backup supply
I think the best way to do what you want is to connect the generator to your consumer unit/fuse box on the grid side of the main CT meter - then add a second CT clamp from the CT2 input, and clamp it to the generator live feed.
The inverter will see everything the generator produces as external ...
- Thu Feb 20, 2025 11:49 pm
- Forum: Customer/End User Help
- Topic: Off grid setup with Generator backup supply
- Replies: 22
- Views: 29576
Re: Off grid setup with Generator backup supply
I don’t know if they are solenoids etc but it’s quite a loud “click click click” as it is negotiating with the input. It’s probably not good for the inverter in the long run.
Hi Max ... I read your post with interest, thanks for all that information. I just wanted to mention that, as someone who ...
Hi Max ... I read your post with interest, thanks for all that information. I just wanted to mention that, as someone who ...
- Mon Feb 17, 2025 6:50 pm
- Forum: Firmware
- Topic: Grid Pressure/Push back Setting added to the K and H1-gen2
- Replies: 18
- Views: 119983
Re: Grid Pressure/Push back Setting added to the K and H1-gen2
I think it's working!
- Thu Feb 13, 2025 7:22 pm
- Forum: Firmware
- Topic: Grid Pressure/Push back Setting added to the K and H1-gen2
- Replies: 18
- Views: 119983
Re: Grid Pressure/Push back Setting added to the K and H1-gen2
Argh! I think I have found my issue perhaps. I was expecing to see a change in the Modbus entity sensor.foxess_grid_ct and there was no change. But actually, we are trying to 'calibrate' that sensor so that it is more accurate -- or we are trying to fool it into pushing back to the grid (that's what ...
- Thu Feb 13, 2025 9:32 am
- Forum: Firmware
- Topic: Grid Pressure/Push back Setting added to the K and H1-gen2
- Replies: 18
- Views: 119983
Re: Grid Pressure/Push back Setting added to the K and H1-gen2
Strange .. not working for me. I had my installer change it to -50 and I still see it behaving just like it always did (typically pulling about 10 watt from the grid).
Master : 1.41
Slave : 1.01
Manager : 1.37
KH10.5
Master : 1.41
Slave : 1.01
Manager : 1.37
KH10.5
- Thu Feb 13, 2025 9:27 am
- Forum: Firmware
- Topic: EPS sensor.foxess_eps_rpower wrong
- Replies: 2
- Views: 3880
Re: EPS sensor.foxess_eps_rpower wrong
Thanks Dave! Yes, that's how I run it too. Not a big deal. Using "load_power" instead may give the same numbers in my use case anyway.
- Wed Feb 12, 2025 11:45 pm
- Forum: Firmware
- Topic: EPS sensor.foxess_eps_rpower wrong
- Replies: 2
- Views: 3880
EPS sensor.foxess_eps_rpower wrong
Hello ... I did a few versions of software updates today and sensor.foxess_eps_rpower is not working correctly. It works when I'm in self-use mode but when pulling from the grid it drops to zero. Meanwhile sensor.foxess_eps_rcurrent is still working fine (showing 14.7A for example when eps power ...
- Wed Feb 12, 2025 6:12 pm
- Forum: Firmware
- Topic: Grid Pressure/Push back Setting added to the K and H1-gen2
- Replies: 18
- Views: 119983
Re: Grid Pressure/Push back Setting added to the K and H1-gen2
Today I got the latest updates from FoxESS on my KH10.5 and asked my installer to give me -20 watts. He knew what I asking for, and did it, but it has not made any difference (I have modbus, so can see grid use updated very frequently and I would notice 20 watts at the grid CT for sure). I also ...
- Fri Feb 07, 2025 7:57 pm
- Forum: Customer/End User Help
- Topic: KH with CS4800 add 8th battery
- Replies: 0
- Views: 3600
KH with CS4800 add 8th battery
Hello:
I believe the original specs were the one master battery plus six additional units. I heard this limit was raised by one so seven units can be in the stack plus the master.
I enquired with my installer and they said "Yes this is true but for a different module battery. unfortunately you ...
I believe the original specs were the one master battery plus six additional units. I heard this limit was raised by one so seven units can be in the stack plus the master.
I enquired with my installer and they said "Yes this is true but for a different module battery. unfortunately you ...
- Thu Mar 28, 2024 3:49 pm
- Forum: Customer/End User Help
- Topic: KH should I update?
- Replies: 6
- Views: 5047
Re: KH should I update?
Yes, it began working again quickly. Each side of the consumer unit (the whole unit is on the EPS output) has an 80A RCD. Probably just a fluke.
- Thu Mar 28, 2024 11:21 am
- Forum: Customer/End User Help
- Topic: KH should I update?
- Replies: 6
- Views: 5047
Re: KH should I update?
Spoke too soon!
Next round did the 'master':
Master : 1.29. Slave : 1.01. Manager : 1.21
That part of the upgrade did throw the device into EPS mode as if the AC power failed which in this case tripped one of the RCDs in the consumer unit meaning power was lost to many circuits in the house. The ...
Next round did the 'master':
Master : 1.29. Slave : 1.01. Manager : 1.21
That part of the upgrade did throw the device into EPS mode as if the AC power failed which in this case tripped one of the RCDs in the consumer unit meaning power was lost to many circuits in the house. The ...
- Thu Mar 28, 2024 11:02 am
- Forum: Customer/End User Help
- Topic: KH should I update?
- Replies: 6
- Views: 5047
Re: KH should I update?
Ok... I was impatient and feeling lucky, so I asked for an upgrade and received it. Only the manager was updated:
Master : 1.27 Slave : 1.01. Manager : 1.21
I'll report back if I find any problems.
Master : 1.27 Slave : 1.01. Manager : 1.21
I'll report back if I find any problems.
- Wed Mar 27, 2024 7:22 pm
- Forum: Customer/End User Help
- Topic: KH should I update?
- Replies: 6
- Views: 5047
KH should I update?
Hello:
I'm hoping maybe William will answer but all are welcome. I have a KH10.5 and I'm on firmware from a month or so ago (Master : 1.27 Slave : 1.01 Manager : 1.19). I know firmware was updated since then. I'm not having any problems but do like to keep current unless there are drawbacks ...
I'm hoping maybe William will answer but all are welcome. I have a KH10.5 and I'm on firmware from a month or so ago (Master : 1.27 Slave : 1.01 Manager : 1.19). I know firmware was updated since then. I'm not having any problems but do like to keep current unless there are drawbacks ...
- Fri Dec 15, 2023 8:47 pm
- Forum: Pre-sales Questions
- Topic: KH-Series 10.5 hybrid inverter software/firmware
- Replies: 15
- Views: 12484
Re: KH-Series 10.5 hybrid inverter software/firmware
This is my inverter ... confirm latest firmware did not give me that function. It did add 'peak shaving' and it did subtract the ability for the foxesscloud to work properly with the inverter. Local control (panel and modbus) are fine. Well, actually I've had some inverter operating system freezes ...
- Fri Dec 08, 2023 9:25 am
- Forum: Customer/End User Help
- Topic: Setting "Low Power" - EPS - UPS
- Replies: 4
- Views: 4183
Re: Setting "Low Power" - EPS - UPS
follow-up question:
regarding firmware parts - am I correct that Manager = inverter's software, Master = main battery (BMS) software, Slave = all the other batteries' software?
regarding firmware parts - am I correct that Manager = inverter's software, Master = main battery (BMS) software, Slave = all the other batteries' software?
- Thu Dec 07, 2023 2:16 pm
- Forum: Customer/End User Help
- Topic: Issue logging into www.foxesscloud.com
- Replies: 6
- Views: 6055
Re: Issue logging into www.foxesscloud.com
It should work, I have both working and the same credentials are used. My web login is using the username, not the email address ... could that be the problem?
I can't give an accurate answer of what you can and can't do, additionally, on the web site, but that's how I prefer to interact with the ...
I can't give an accurate answer of what you can and can't do, additionally, on the web site, but that's how I prefer to interact with the ...